Permitted Solvents; Permitted Solvent Drums; Collecting Tray; Preparation For Use - Hedson Drester Boxer Double Combo Manual De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Ventilation
The air-driven extractor must be connected to a metal ducting
to lead the exhaust outdoors. An alternative is to lead it into a
hood that is in turn connected to a suitable ventilation system
approved for Zone 1. This hood should have an open design so
as to avoid constant extraction (see illustration 10).
The metal ducting may not be longer than 15 metres, and must
be connected in such a way as to ensure grounding.

PERMITTED SOLVENTS

The unit has two separate areas for cleaning:
1. The automatic washer (item 1 illustration 1). In this washer
solvents and solvent mixtures
cleaning, such as acetone, toluene, isobutanol, xylene that
are listed as Group IIA according to IEC 79-20 (EN 60079-
20), water or water-based solvents can be used.
2. The sink (item 2 illustration 1). In this sink
can be used.
based solvents
The solvent must have a pH value between 4 and 10.
not to mix the solvents.
informed of what solvents are being used, at all times.
Never use any solvent if it is not provided with an MSDS (Mate-
rial Safety Data Sheet). Read the MSDS carefully, and follow all
the instructions and procedures provided in the MSDS. If un-
sure, or if more information is needed concerning the solvent,
please contact your solvent supplier.
Do not add other chemicals to the solvent including, but not
limited to, kerosene, gasoline, detergents, fuel oil or chlorinated
solvents.

PERMITTED SOLVENT DRUMS

The DRESTER BOXER DOUBLE C2 can be used with different
types of drums, but they must comply with the following:
– The drums must fi t into the unit
– The drums must be leak-free.
– The drums must be made of a conductive material.
– Check for local regulations concerning max allowed volume
for keeping solvent in the unit
Solvent drums are not provided by Hedson Technologies, thus
Hedson Technologies does not take any responsibility for the
drums. Follow the solvent supplier's instructions carefully.
4
intended for spray-gun
water or water-
Be sure
It is important that all users are

COLLECTING TRAY

The unit must be installed in such a way as to prevent ac-
cidental leakage of solvent from spreading into a drain water
system, thus representing a hazard to the environment. This can
be done by:
– installing the unit in a location where fl oor and walls can
hold any accidental drum leakage, or
– equipping the unit with a collecting tray beneath the
solvent drums that is large enough to hold the volume of at
least one leaking drum.
PREPARATIONS FOR USE
Drum plugs
There are several types of solvent drums on the market, each
with different diameter of the opening. With the unit, card-
board boxes with a selection of tapered plugs are supplied (see
illustration 3). Select the plugs that fi t well into the opening of
the drums, and fi t them onto the drum adaptors of the hoses
(see illustration 4).
Solvent drums
Remove the front panel (item 5 illustration 1) by lifting it up-
and-out.
Remove the foot-pedal console (items 6 illustration 1) by lifting
it up and folding it out to the side (see illustration 2).
Place the drum with solvent for the Automatic wash under the
unit (item 2 illustration 2). Insert the group of hoses containing
the drain hose from the automatic washer into this drum (item
4 illustration 2). Make sure that the hoses are properly led well
down into the drum, and that the opening is well sealed by the
tapered plug.
Place a drum with water or water-based solvent for the Manual
wash under the unit (item 3 illustration 2). ). Insert the group
of hoses containing the white suction hose and the drain hose
from the manual sink into this drum (item 5 illustration 2).
Make sure that the hoses are properly led well down into the
drum, and that the opening is well sealed by the tapered plug.
Operating instructions
Operating instructions should be formulated on the basis of
this manual and translated into the language spoken by the
employees. It should always be available close to the machine.
To avoid confusion, the employees must be informed about the
solvent currently being used in the machine.
16025 rev 2012-02-29

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Db22c2Di22c2

Tabla de contenido