Checking the preservation of the flexible hose:
It does not show cracks, cuts, marks or burns on the outer parts and full length.
The fixing clamps are not rusted.
The expiration time has not elapsed.
IMPORTANT : If an abnormality is found again, do not repair the pipe, replace it.
IMPORTANT : Once installation is complete, check the perfect seal of each pipe, using a soapy solution,
never a flame.
Changing the injectors
Adapting to different types of gas:
This appliance is delivered preset to the network gas (natural gas).
For any change of gas, you must do the following three things:
1. Adapt the gas connection (above)
2. Change the injectors
3. Set taps idle
The injectors required for adaptation to butane / propane are in the wallet containing the instructions.
Mounting of injectors
Each injector is identified by a number engraved above.
Change the injectors with an appropriate key as follows:
Remove the pan, hats and heads of all burners.
Unscrew using the appropriate key injectors located in the bottom of
each pot and remove them
Climb instead the injectors provided. For this, screw them first
manually until the injector blocking then insert the key on the injector
and then tighten.
Burner idle adjustment
To adjust the minimum level:
Turn the button until the minimum flame position
Reset button
In case of conversion of the natural gas to the LPG (bottled
•
gas), screw the brass screw on each valve
In case of conversion of LPG to the natural gas, unscrew a
•
quarter turn the brass screw on each faucet until a steady
flame.
Replace the controllers and quickly turn the knob from the maximum position to the minimum position so that
the flame will not be extinguished and the setting is correct.
NOTE : it is recommended that the execution of operations should be entrusted to an authorized
specialized service.
25