INDICATORS AND OTHER FUNCTIONS

Tank Full Light
Red light will be on and the unit will beep when the tank is ready to be emptied, or
when the tank is removed or not replaced in the proper position. The water level control
switch shuts off the dehumidifier when the tank is full,or when the tank is removed or not
replaced in the proper position. Empty and replace to resumeoperation.
Auto Defrost
The appliance will defrost automatically as programmed once the coil sensor detects
temperature is too low, and the defrosting indicator will light up at the same time. Once
defrosting has finishes, the appliance will recover to previous running mode.
Humidistat control and fan/compressor operation
When the selected humidity is 2 % lower than the user selected humidistat setting; the
dehumidifier's compressor will be shut off automatically.
When the humidity is equal or higher than user selected humidity the compressor will
restart once the 3 minutes delay compressor protection expires.
Auto Restart
If the unit stops off unexpectedly due to the power cut, it will restart with the previous
function selected automatically when the power resumes.
Power
After the unit has stopped, it is not recommended to resume operation for at least
10 minutes. This is to protect the compressor. Operation can resume after this period
lapses. When the unit is restarted there is a 3 minutes delay before compressor will start.
Self-diagnostic
The dehumidifier is an micro-CPU controlled device able of self-diagnostics. The LCD
display may also show the error and protections codes.