Tornado MINI-MARATHON 425 Manual Del Usario página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
Machine does not
operate.
Brush motor does not
operate.
Solution pump does not
operate.
Vacuum motor does not
operate
Poor solution pick-up.
Uneven or no spray.
CAUSE
Faulty switches or wiring.
Faulty power cord.
Building circuit breaker
tripped
Brush motor circuit
breaker tripped.
Switch not pushed.
Loose or broken brush
belt.
Faulty switch or wiring.
Faulty brush motor.
Solution pump circuit
breaker tripped.
Switch not pushed.
Faulty switch or wiring.
Faulty solution pump
motor.
Loose or broken wiring.
Faulty main power
switch.
Defective vacuum motor.
Worn carbon brushes.
Defective recovery tank
cover gasket.
Clogged float shut-off
screen.
Accessory tool vacuum
hose port cover is loose
or missing.
Loose vacuum hose
cuffs.
Pulling machine too fast.
Plugged spray tips.
Improper spray tip size or
spray angle.
Clogged solenoid valve.
Worn spray tips.
Solution tank low or
empty.
Faulty solution pump.
Pump needs priming.
14
SOLUTION
Contact Tornado.
Contact Tornado.
Reset breaker.
Let motor cool and reset
brush motor breaker
button at rear of machine,
Push solution switch.
Contact Tornado
.
Contact Tornado.
Contact Tornado.
Let pump cool and reset
pump breaker button at
rear of machine.
Push solution switch.
Contact Tornado.
Contact Tornado.
Contact Tornado.
Contact Tornado.
Contact Tornado.
Contact Tornado.
Replace gasket.
Open recovery tank
cover and clean lint off
screen.
Check vacuum hose port
cover.
Secure connections
under cover.
Slow down cleaning
process.
Clean or replace tips.
Replace with proper tips
.
Contact Tornado.
Replace spray tips.
Refill solution tank.
Contact Tornado.
Prime pump by pressing
solution hose coupler
tip located at front of
machine.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

98150

Tabla de contenido