TL 105 - TL 108
Maintenance
6.1.d.c - Adjusting the belt tension (Fig. 6)
•
Operating on the outfeed side, undo the screws (1)
and remove the panel (2).
Using an Allen wrench, adjust the belt tension by
acting on the screw (3).
6.2 - RESETTING THE SAFETY THERMOSTAT
(FIG.7)
Operate as follows to reset the safety thermostat:
•
Undo the screws (1) that fasten the left side panel (2).
•
Press the red button (3) to reset the safety thermostat
located in the technical compartment.
2
3
3
1
FIG. 6
1
1
FIG. 7
2
EN - 39