Angelo Po Combi-Duo 6x1/1 GN Instrucciones De Instalación Y Gráficos página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
Damages based on installation not comply-
ing with the directives given hereunder are
not covered by the warranty terms.
He following Combi-Duo kits are available:
top
bottom
6x1/1 GN (E/G)
6x1/1 GN (E) / 10x1/1 GN (E)
Movable
Art.-No.: 60.70.378
6x1/1 GN (E/G)
6x1/1 GN (E) / 10x1/1 GN (E)
On wheels
Art.-No.: 60.70.380
6x1/1 GN (E/G)
6x1/1 GN (E) / 10x1/1 GN (E)
Legs 150mm
Art.-No.: 60.70.379
6x2/1 GN (E/G)
6x2/1 GN (E) / 10x2/1 GN (E)
Movable
Art.-No.: 60.70.384
6x2/1 GN (E/G)
6x2/1 GN (E) / 10x2/1 GN (E)
On wheels
Art.-No.: 60.70.386
6x2/1 GN (E/G)
6x2/1 GN (E) / 10x2/1 GN (E)
Legs 150mm
Art.-No.: 60.70.385
Installation drawings and schematics as well as
exact measurements and height of the top
rail please see dimensioned drawing in the separate
drawing manual.
The picture numbers in this manual also relate to
the separate drawing manual.
Legend of dimensioned drawing:
1 = Height of top rail
2 = Height of drive in upper unit
3 = Height of drive in lower unit
4 = Drain height upper unit
5 = Drain height lower unit
For exact informations regarding water-,
drain-, gas connection and power supply
please refer to installation instruction of
units.
(E=electric; G=gas)
- 7 -
A) Bottom unit:
- Remove cover frame of the care pump
container, by:
Loosing the two screws on the front cross part of
the cover frame.
- Undo lower part of the unit's leg
- Loosen upper part of the unit's leg with long
spanner 15 mm.
Combi-Duo movable:
- Put the frame with the rolls to the installiation
site and check for leveled positioning.
- Minor uneveness (10 mm) can be compensated
using the rolls 60 mm (pic. B pos. 18).
- Fit the frame to the bottom of the unit using
the screws of the legs and the washer of the
kit (pic. B item 19).
- Fit the selected rolls to the frame.
- Fit water hose to the unit and check for
leakage.
Combi-Duo on wheels:
- Fit the extension pipe (pic. C item 27) to the
water manifold of the unit.
- Fit the frame to the bottom of the unit using
the screws of the legs and the washer of the
kit (pic. C item 26).
- Fit the casters to the frame.
- Connect water supply hose to the unit and
check for tightness.
- 6x1/1 GN / 10x1/1GN:
Remove screws of the left side panel. Secure
side panel with the holding bracket
(pic. C item 28)
GB
pic. 7A
pic. 7
pic. 1/2
pic. 3/4