Safety Stop Function
XC25:1
2
V1
+5 V
S2
X1:
DC+
Rectifier
X1:
R/L1
S/L2
T/L3
X1:
DC-
+5 V
S1
V1
XC25:3
4
V1 = inverter internal voltage.
CFW-11M (more specifically power units) do not have R/L1, S/L2 and T/L3 terminals, They are fed by a DC voltage
only, SRBXX board is located on the control unit – in this case, K1 and K2 safety relays actuate on the fiber optic
transceivers that send PWM pulses to power units (UP11-XX) for firing the IGBTs.
Figure 1: Basic block diagram of safety stop function available in CFW-11, CFW-11M and CFW70x inverter
6 | CFW-11, CFW-11M, CFW70X