Parameter modification menu [TSP]
Press the heating buttons to scroll the list, press the button
press the DHW, buttons, confirm with the button
Table 10- Transparent Parameters Table
Index
Description
Boiler type selection
b01
Boiler type
b02
Gas type
b03
System water pressure protection selec-
b04
tion
Summer/Winter mode
b05
Variable input contact operation selection
b06
Relay card LC32 selection
b07
Not implemented
b08
Fault 20 status selection
b09
Not implemented
b10
Hot water tank preparation
b11
Hot water tank priority
b12
Heating priority
b13
DHW factor (not used)
b14
Not implemented
b15
Not implemented
b16
Not implemented
b17
DHW mode activation flow rate (not
b18
used)
DHW mode deactivation flow rate (not
b19
used)
Flue material selection
b20
Not implemented
b21
Not implemented
b22
Standard flue shutdown maximum tem-
b23
perature
PVC flue shutdown maximum tempera-
b24
ture
CPVC flue shutdown maximum tempera-
b25
ture
Not implemented
b26
Calibration procedure [AUTO SETUP]
b27
Not implemented
b28
Restore Factory Values
b29
328
BlueHelix HiTech RRT H
Range
2 = HEATING ONLY (also with OPTIONAL HOT WATER TANK)
1 = 18 H
2 = 28 H
3 = 34 H
0 = Natural gas
1 = Liquefied gas
2 = Propane-air
0 = Pressure switch
1 = Pressure transducer
0 = WINTER - SUMMER - OFF
1 = WINTER - OFF
0 = Flowmeter exclusion
1 = System thermostat
2 = Second room therm.
3 = Warning/Alert
4 = Safety thermostat
0 = External gas valve
1 = Alarm
2 = System filling solenoid valve
3 = Legionella pump
4 = Second heating pump
5 = Alarm2
6 = Burner lit
7 = Frost protection On
--
0 = Deactivated
1 = Enabled (only for versions with pressure transducer)
--
0 = Fixed primary (P44)
1 = Linked to DHW Setpoint (P51)
0 ÷ 255 min
0 ÷ 255 min
0 - 1
--
--
--
0-100 l/min/10
0-100 l/min/10
0 = Standard
1 = PVC
2 = CPVC
--
--
60-110°C
60-110°C
60-110°C
--
5 = Calibration procedure [AUTO SETUP] enabled
All other values = Calibration procedure [AUTO SETUP] disabled
(See "Calibration procedure [AUTO SETUP]" on page 326)
--
See *** '* Restore Factory Values' on page 330 ***.
cod. 3541V480 - Rev. 00 - 04/2021
to display the value To modify,
or cancel with the button
Default
2
1 = BLUEHELIX HITECH RRT 18 H
2 = BLUEHELIX HITECH RRT 28 H
3 = BLUEHELIX HITECH RRT 34 H
0
1
0 = Enabled
2
0
24
0
--
0
30
15
0
3
--
--
25
20
0
--
--
105
93
98
--
0
--
0
.