4.6 Wiring diagram
16 Fan
32 Heating circulating pump
34 Heating temperature sensor
44 Gas valve
72 Room thermostat (not supplied)
81 Ionization/ignition electrode
95 Diverter valve
138 External probe (optional)
44
X04-8
X04-9
230V
X04-1
50Hz
GROUND
95
X04-5
X04-6
X04-7
288
16
X01-3
X01-4
X01-5
X01-6
X01-7
Attention: Remove the jumper on the terminal block before connecting the room thermo-
A
stat or the remote timer control.
If wanting to connect more zones of the hydraulic system that are controlled by thermo-
stats with voltage-free contact and the timer control has to be used as a remote control for
the boiler, it is necessary to connect the voltage-free contacts of the zones to terminals 1-
2 and the timer control to terminals 5-6.
ALL CONNECTIONS TO THE TERMINAL BLOCK MUST BE WITH VOLTAGE-FREE
CONTACTS (NOT 230V).
EN
32
X05
8
1
9
1
X07
X11
LC32
fig. 65- Wiring diagram
cod. 3541V480 - Rev. 00 - 04/2021
139 Remote timer control (optional)
155 Hot water tank probe (optional)
186 Return sensor
191 Fume temperature sensor
288 Frost protection kit
294 Pressure transducer
A
ON/OFF switch (configurable)
191
34
186
14
1
5
1
X08
X09
X16
294
N
L
138
A
5
6
155
1.8kOhm
10kOhm
81
72
139