Ferroli BlueHelix HiTech RRT H Instrucciones De Uso, Instalación Y Mantenimiento página 329

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BlueHelix HiTech RRT H
Index
Description
Heating ramp
P30
Heating standby time
P31
Heating Post-Circulation
P32
Pump operation
P33
Pump modulation DeltaT
P34
Modulating pump min. speed
P35
Modulating pump start speed
P36
Modulating pump max. speed
P37
Pump deactivation temperature during
P38
Post-Circulation
Pump activation hysteresis temperature
P39
during Post-Circulation
Heating user max. setpoint
P40
Max. output in heating
P41
Anti-Legionella function frequency
P42
Hot water tank hysteresis
P43
Hot water tank preparation flow
P44
DHW standby time
P45
DHW user max. setpoint
P46
DHW pump Post-Circulation
P47
Max. output in DHW
P48
Not implemented
P49
Not implemented
P50
Hot water tank Off Delta
P51
Not implemented
P52
Not implemented
P53
System pre-circulation time
P54
System filling mode
P55
Minimum system pressure limit value
P56
System nominal pressure value
P57
Maximum system pressure limit value
P58
Not implemented
P59
Frost protection power
P60
Minimum power
P61
Fan minimum speed
P62
Fan On speed
P63
EN
Range
10÷80
(ex. 10=20°C/min, 20=12°C/min, 40=6°C/min, 80=3°C/min)
0-10 minutes
0-255 minutes
0 = Continuous pump (active only in winter mode)
1 = Modulating pump
0 ÷ 40°C
30 ÷ 100%
90 ÷ 100%
90 ÷ 100%
0 ÷ 100°C
0 ÷ 100°C
20 ÷ 90°C
0 ÷ 100%
0 = OFF
1÷7 = Days
0 ÷ 80°C
0 ÷ 100°C
30 ÷ 255 seconds
40 ÷ 70°C
0 ÷ 255 seconds
0 ÷ 100%
--
--
0 ÷ 20°C
--
--
0 ÷ 60 seconds
0 = Disabled
1 = Automatic
0-8 bar/10 (Only for boilers with water pressure sensor)
5-20 bar/10 (Only for boilers with water pressure sensor)
25-35 bar/10 (Only for boilers with water pressure sensor)
--
0 ÷ 50% (0 = minimum)
0 ÷ 50% (0 = minimum)
DO NOT MODIFY
(The parameters are automatically updated)
DO NOT MODIFY
(The parameters are automatically updated)
cod. 3541V480 - Rev. 00 - 04/2021
Default
40
4
15
1
20
30
90
100
55
25
80
BLUEHELIX HITECH RRT 18 H = 75
BLUEHELIX HITECH RRT 28 H = 100
BLUEHELIX HITECH RRT 34 H = 100
0
2
80
120
65
30
BLUEHELIX HITECH RRT 18 H = 75
BLUEHELIX HITECH RRT 28 H = 100
BLUEHELIX HITECH RRT 34 H = 100
--
--
10
5
10
30
0
4
7
28
--
0
0
G20/G230:
BLUEHELIX HITECH RRT 18 H = 47
BLUEHELIX HITECH RRT 28 H = 47
BLUEHELIX HITECH RRT 34 H = 49
G30/G31:
BLUEHELIX HITECH RRT 18 H = 49
BLUEHELIX HITECH RRT 28 H = 49
BLUEHELIX HITECH RRT 34 H = 48
G20/G230:
BLUEHELIX HITECH RRT 18 H = 160
BLUEHELIX HITECH RRT 28 H = 160
BLUEHELIX HITECH RRT 34 H = 140
G30/G31:
BLUEHELIX HITECH RRT 18 H = 152
BLUEHELIX HITECH RRT 28 H = 152
BLUEHELIX HITECH RRT 34 H = 132