Master Forge BG1793B-A Manual De Instrucciones página 34

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
PROBLEM
Low heat
1. Low heat is found in natural
with the knob
gas models.
in "HIGH"
2. Ports are blocked.
position.
3. LP tank has run out.
The propane regulator assembly
incorporates an excess flow device
designed to supply the grill with
Low heat,
sufficient gas flow. Rapid changes in
LP gas.
pressure can trigger the excess flow
device, providing a low flame and
low temperature.
Gas pressure is significantly affected
Low heat,
by gas line and length of gas line
natural gas.
from house gas line.
POSSIBLE CAUSE
CORRECTIVE ACTION
1. This model is set for 7 in. natural gas
usage. Please check your natural gas
supply system to have correct gas
pressure. Regulator is not needed for
NG model.
Check the orifice if you installed NG
nozzles. Conversion kit provides the
following nozzles:
Burner
Main Burner
Rotisserie Burner
2. Clear ports of any obstructions.
3. Refill the LP tank.
Please follow these instructions:
1. Make sure all burners are "OFF".
2. Open the tank valve and wait 5
minutes.
3. Light the burner one at a time
following the lighting instructions listed
on the door liner and Page 26 and 27.
Check your gas line and make
corrections by following the chart below:
From House to Grill
Distance
Up to 25 ft.
26 – 50 ft.
51 – 100 ft.
Over 101 ft.
34
Orifice Size
1.45mm
1.30mm
Tubing Size
3/8 in. DIA
1/2 in. DIA
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.
3/4 in. DIA

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

0503225

Tabla de contenido