Electrical Connections - Jacuzzi SALON Serie Instrucciones Para La Instalación Y El Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Salon™ Spa Bath

Electrical Connections

Risk of electric shock. Connect only to a dedicated circuit protected by a GFCI.
When using electrical products, basic precautions should always be followed:
Always follow local building and electrical codes.
Grounding is required. The unit should be installed and grounded by a qualified electrician.
Two separate GFCI protected circuits are required.
A separate, dedicated 240VAC, 20 Amp GFCI circuit is required for the heater and pump/motor.
A separate, dedicated 120VAC, 15 Amp GFCI circuit is required for the blower.
Risk of component overheat. Do not use electric extension cord to power this unit.
Operating the motor/pump without enough water in the bathtub can cause leaking and permanent damage.
At initial startup, the 8 button electronic control system enters an automatic self diagnostic program for 15-20
seconds. During the diagnostic program, the system will not accept user commands.
Blower , Pump and motor
The information provided below is applicable to all
Jacuzzi Luxury Bath units. Determine which set up
you have (blower or pump/motor) and follow those
instructions.
The electrical outlet must be mounted 4˝ (101mm)
above the floor line, or in accordance with local
building and electrical codes.
Blower
-
The blower requires a dedicated 120 VAC, 15AMP,
GFCI protected circuit. The electrical outlet is not
supplied.
Pump/motor
-
The pump/motor and heater requires a dedicated
240 VAC, 20 AMP GFCI protected circuit. The
electrical outlet is not provided.
-
Power cords from the heater and the pump/motor
are routed to a fused junction box at the factory. A
supplied power cord from the junction box with a
240 VAC plug connects to the customer-supplied
GFCI protected circuit.
-
Bonding lugs are provided on the heater and motor
to satisfy local electrical codes.
-
At initial start-up, test GFCI units for proper
operation. Follow manufacturer's instructions on
proper use.
If the GFCI units indicate a malfunction, per manufacturer's instructions, turn OFF power and do not use the
bathtub until the source of the problem has been identified and corrected.
Installation and Operation
(101mm)
120V GFCI Protected,
Dedicated Circuit (Not Supplied)
(101mm)
240V GFCI Protected,
Dedicated Circuit (Not Supplied)