5. Installation Checkout
Connect the drain tailpiece to the P-trap.
Using the key provided, remove the aerator from the spout.
If applicable, uncover the drain.
Turn on the main water supply and check for leaks. Adjust as
needed.
Allow the water to run through the spout for about 1 minute to
remove any debris. Check for leaks and adjust as needed.
Temporarily cover the sensors on the faucet or close the water
supplies.
Using the key provided, reinstall the aerator to the spout.
Uncover the sensors on the faucet or turn on the water supplies.

Troubleshooting

Symptoms
1.
No water flow.
1124217-2-D
Aerator
Key
Probable
Recommended Action
Causes
A. Filter is
A. Clean or replace the
plugged.
filter.
B. Sensor
B. Wipe the sensor eyes
eyes are dirty.
with a damp soft cloth.
Wipe dry with a dry soft
cloth.