IMPORTANT NOTES!
Cleaning Products: Do not use abrasive cleaning agents or concentrated bleach when cleaning. Do not use any of the following cleaning products: automatic dishwashing
detergents, oven cleaners, steel wool or other abrasive pads.
Cover: Do not wash cover door, handle or back cover in dishwasher. It is recommended that the handle not be disassembled during cleaning. However, if you choose to
disassemble the handle from the cover, make sure to not over-tighten it when reattaching it to the cover. Doing so will cause damage.
Container: Do not let mixtures, liquids or food products dry in the container. Rinse after use. Dry product may lock around the blade and weaken/tear the bearings seal
when restarted. Do not place containers in the freezer. Extremely low temperature combined with hot ingredients and/or the immediate rapid action of the blade may crack
the container. Microwaving and automatic dishwashing are not recommended.
Blade Assembly: Do not soak the blade agitator assembly.
* Be sure to uplug the blender and wring excess water out of cloth or sponge when cleaning around the controls or any electrical part.
** Recommended sanitizing solution: 1.5 tsp. / 7,4 ml institutional or household bleach in 2 qt. / 1,9 L water.
Motor Base/Control Panel: Unplug the power cord and gently wash the outside surface with a damp soft cotton cloth moistened with a mild solution of warm water* and
nonabrasive detergent or nonabrasive liquid spray cleaner. Be careful to not scratch or scrub the display window on the control panel. Never immerse the motor base in water or
other liquid. Dry with a soft cotton cloth.
Lid: Wash in warm, soapy water. Rinse clean under running water and dry.
Cover Door: The cover can be removed and cleaned by placing under running water and washing with a soft cloth. Wipe dry and replace back on the base.
Container Centering Pad: Remove the centering pad. Wash the pad in warm, soapy water. Rinse clean under running water and dry. Reassemble before use. Replace the sound
enclosure. The centering pad should be flat on the motor base.
Container: The Advance® container has been designed to be chemical resistant. However, for maximum container life, hand washing is recommended.
To Clean: Wash all container parts in warm soapy water. Rinse and drain. Do not soak the blade assembly.**
To Sanitize: After all solid residue is removed, fill container 3/4 full with a sanitizing solution mix.*** Return container to motor base and firmly position the two-piece lid. Run
machine on a high speed for 30 seconds. Turn machine off and allow mixture to stand in the container for an additional 1 1/2 minutes. Pour out contents. Return container to
motor base and run machine empty for an additional 5 seconds. Do not rinse after sanitizing. Allow container to air dry.
10
c
y
m
a R i n g f o R
o u R
a c h i n e