Safety; Specifications - Facom 714 Guía De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
GB

Safety

- Never use direct or alternate networks above 600V in respect of earth.
- Never use direct or alternate networks above 600V in respect of earth.
- This multi-function tester is protected by a double or reinforced insulation. It's
electrical safety does not require grounding.
- This multi-function tester is designed for indoor use, at an altitude < 2000m, and in
an environment offering a pollution level 2 (as per EN 61010-1)
- Use this multi-function tester for measuring in category II up to 600V, and category
III up to 300V.
- Measurement category II: circuits connected directly to the low voltage facility.
- Measurement category III: building's facility.
- Never open this multi-function tester when it is connected to a power source.
- Never measure resistance on a live circuit.
- Before measuring, check the cords and switch are set properly.
- Never connect to a circuit for measuring when the multi-function tester's case is
open.
To ensure safe use, always apply the instructions.
The following symbols are used:
! Caution ! Danger ! Read the instructions.
Tester fully protected by double or reinforced insulation.
Technical specifications
Dimensions:
Weight:
2 batteries:
Operating time: 300 hours
Automatic deactivation after 10 minutes without action on controls or functions.
NB: Activation by actuating the switch or pressing a key.
Battery low indicator. NB: The tester's accuracy is not guaranteed if the battery low
indicator is On.
Operating temperature:
Storage temperature:
Relative humidity (operating):
Relative humidity (storage):
Protection class:
Self-extinguishing:
Free fall:
Vibration:
Shock:
EMC:
Liquid crystal display, 3999 measuring points
Bargraph with 37 segments, resolution 33 mV per bar, scale from 0 – 1.2V
Buzzer
Supplied with red rubber protection, a set of 2 contact tip cords, an instruction
manual, and 2 LR6 batteries, non installed.
14
174 x 66 x 43 mm without casing – 182 x 74 x 61 with casing
250g without casing – 320g with casing
1.5 Volt
(LR6)
18000 1-min measurements
Continuous beep for continuity test
Discontinuous beep when pressing keys and excess indication.
- 10°C to + 55°C
- 20°C to +70°C
< 80% RH
< 90% RH
(up to 45°C)
IP 40
(as per EN 60529)
V1 and V2
(as per UL94)
1m
(as per CEI 68-2-32)
0.75mm
(as per CEI 68.2.6)
0.5 Joule
(as per CEI 68.2.27)
complies with EN 61326-1, devices in industrial
environments.
.

Publicidad

Tabla de contenido
loading

Tabla de contenido