bolting Down Your Safe
bolt down instructions...continued
5
Move the safe aside to clear both marked spots for drilling.
Drill into the floor:
6
Replace the safe in the desired position, with the holes in the safe aligned
7
with those in the floor.
8
F
F
F
NOTE: • The safe should not be bolted to a wall, this will compromise the fire rating.
Drill holes through the feet only. Do not drill through the back or sides.
• Bolting/unbolting the unit is at the consumer's expense and discretion.
• Sentry Group is not responsible for any costs incurred if the unit is to be replaced.
For products that do not come with a bolt down kits:
Go to www.sentrysafe.com to find recommended hardware and instructions.
For wood: Using the 9⁄32" drill bit, drill a hole 2 1⁄2"
A
(64 mm) deep in each marked spot.
For masonry: Using the 3⁄8" drill bit, drill a hole 2 1⁄2"
b
(64 mm) deep in each marked spot. Install a masonry
anchor in each hole.
Securing the safe:
For wood: Pass each lag screw through a washer,
A
then through the safe and into a hole. Tighten with
the wrench.
For masonry: Pass each lag screw through a washer,
b
then through the safe and into a masonry anchor.
Tighten with the wrench. Place masonry anchors into
the holes in the floor.
11