Connect the earth cable to the Positive output
terminal (plus) -
- on the front of the unit and the
B
earth clamp to the workpiece.
Connect the Tig torch to the negative output terminal
(minus) -
- on the front of the unit.
E
TIG WELDING WITH FRONT B
14
16
Figure 19 - Power Source Control Panel - TIG
16
Press the key Mode to select the TIG Mode ,
the corresponding LED lights up.
Regulation knob
18
for adjusting the welding Current (Amps). The
adjusted value can be read in the display - 4 - in
the separate wire feeder and in the display - 14 in
the power source.
TIG WELDING WITH FRONT A
1
Press the key – 1 – to enter the
TIG, the corresponding LED lights up.
In GOUGING process, connect the ground cable
on the negative (minus) -
gouging torch on the positive (plus) -
Connect torch with an external air compressor.
Mode Key
Press Mode key to enter the gouging menu.
.
OPERATOR POINTS - MEMORY
Selection Key
3
For saving and recalling the points that the operstor
can customize. In MMA and TIG Mode it is possible
to save max 10 memories, in MIG MAN and MIG
SYN Mode max is 200.
To save the parameters proceed as follows:
•
Press the key - 3 -, the LED - 5D - and the
LED Memory light up;
•
Turn the right Regulation Knob - 9 - to select
the number of the operator point to be sa-
ved. The right display - 5 - views the operator
point number.
TIG WELDING
GOUGING (ONLY SOME MODELS)
- and connect the arc
E
-.
L
SAVE & RECALL
4
4B
8
18
17
Figure 20 - Control Panel - TIG
Left Regulation Knob - Current
8
For adjusting the welding current (A) on a range
from 5 to maximum current value.
Left Display - Current
4
Visualization in Amp, LED 4B is lit
Selection Key
3
With a short pression it recalls and charges the points
customized by the operator. With a long pression it
saves the parameters adjusted by the operator in the
operator point, 5D LED is lit, the operator point can
be read in the right display - 5 -.
Refer to the section "Save & Recall".
Regulation knob - Current
18
For adjusting the welding current (A) on a range
from 5 to maximum current value. The adjusted va-
lue can be read in the display - 14 in the power
source.
•
To save the parameters hold the key - 3 -;
•
The display reverts to views the welding para-
meters. The LED - 5D - and the Memory LED
turn OFF.
To open and charge a memory previously saved
memory proceed as follows:
•
Press the key - 3 -;
•
Turn the right Regulation Knob - 5 - to select
the number of the desired operator point;
•
Press again the key - 3 - or the key - 1 -.
1
2
3
5
5D
9
17