Operating Conditions - Lenze L-force 9400 Serie Instrucciones Para El Montaje

Ocultar thumbs Ver también para L-force 9400 Serie:
Tabla de contenido

Publicidad

4
Technical data
General data and operating conditions

Operating conditions

Environmental conditions
Climate
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
Transport
Operation
Assignment of filters to standard devices
)
Note!
The operation of the regenerative power supply modules is only permissible
with an assigned mains filter.
Mains filter
E94AZMR0264SDB
E94AZMR0264LDB
E94AZMR0474SDB
E94AZMR0474LDB
E94AZMR0xxSDB −> "short distance"
54
IEC/EN 60721−3−1
IEC/EN 60721−3−2
IEC/EN 60721−3−3
EN 61800−5−1
2
(9.81 m/s
= 1 g)
IEC/EN 60721−3−2
EN 61800−2
Germanischer Lloyd
IEC/EN 60068−2−6
Regenerative power supply module
Standard device
E94ARNE0134
E94ARNE0244
E94AZMR0xxLDB −> "long distance"
l
1K3 (−25 ... +60 °C)
2K3 (−25 ... +70 °C)
3K3 (−10 ... +55 °C)
Current derating from +45 ... +55 °C: 2.5 %/°C
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of 5 %/1000 m
Degree of pollution 2
2M2
2 ... 9 Hz: Amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
200 ... 500 Hz: acceleration resistant up to 15 m/s
5 ... 13.2 Hz: Amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
10 ... 57 Hz: Amplitude 0.075 mm
57 ... 150 Hz: Acceleration resistant up to 1 g