REGOLAZIONI - ADJUSTMENTS - RÉGLAGES - EINSTELLUNGEN - REGULACIONES
I
Trimmer T.L. = Regolazione tempo lavoro
(min.10", max.80").
Trimmer T.C.A. = Regolazione tempo di
chiusura automatica (min.0", max.120").
GB
Trimmer T.L. = Adjustment of operating
time (min.10", max.80").
Trimmer T.C.A. = Adjustment automatic
closing time (min.0", max.120")
D
Trimmer T.L. = Einstellung der Laufzeit
(min.10", max.80").
Trimmer T.C.A. = Zeiteinstellung
Schließautomatik (min.0", max.120").
-8-
Alimentazione accessori 24V (a.c.) max. 40W
24V (a.c.)Powering accessories (max 40W)
Alimentation accessoires 24V (c.a.) max. 40W
Zubehörspeisung 24V (Wechselstrom) max. 40W
Alimentación accesoios 24V (a.c.) max. 40W
Collegamento elettroserratura 12V (a.c.) 15W max.
12V (a.c.) 15W max. connection for electrically-actuated lock
Connexion serrure électrique 12V (c.a.) 15W max.
Anschluß Elektroschloß 12V (Wechselstrom) 15W max.
Conexión electrocerradura 12V (a.c.) 15W max.
Collegamento antenna
Antenna connection
Connexion antenne
Antennenanschluß
Conexión antena
N.B. A bridge
N.B: Tous les
connection must
contacts et les
be applied across
poussoirs (N.F.)
all (N.C.) contacts
doivent être
and normally-
courtcircuités
closed pushbutton
sur la plaque à
connections
bornes s'ils ne
which are not
sont pas
connected to
connectés aux
accessories.
accessoires.
Apply the bridge
connections at the
terminal board.
HINWEIS:Alle
Kontakte und
Tasten (N.C.), an
die kein Zubehör
angeschlossen
ist, müssen auf
dem Klem-
menbrett
kurzgeschlossen
werden.
QUADRO COMANDO
T.L.
T.C. A .
ZL160
1
2
3
4
REGOLAZIONE TRIMMERS
TRIMMERS ADJUSTMENT
RÉGLAGE TRIMMERS
EINTELLUNG TRIMMERS
REGULACIÓN TRIMMERS
F
Trimmer T.L. = Réglage du temps de
fonctionnement (min.10", max.80").
Trimmer T.C.A. = Réglage du temps de
fermeture automatique (min.0", max.120").
E
Trimmer T.L. = Regulación tiempo de
trabajo (min.10", max.80").
Trimmer T.C.A. = Regulación cierre
automático (min.0", max.120").
NOTA:Todos los
contactos y
pulsadores
(N.C.) no
conexionados a
accessorios
deben ser
cortocircuitados
sobre la regleta
de bornes.
T.L.
T.C.A.