Remote Operation; Remote Closure 4 Behavior; Remote Closure 4 Application - Booster Pump Support - Zodiac JEP-R Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 10
ENGLISH
Pump
VS-FHP 1.0
VS-FHP 2.0
Figure 6.
DIP Switch Settings
3.
Connect the other side of the remote contact closure
to INPUT 1, INPUT 2, INPUT 3, or INPUT 4
terminal on J3 REMOTE CONTROL connector of
the controller, depending on which speed is to be
controlled.
4.
Turn on all switches and the main breaker feeding
power to the variable-speed pump.
5.
Verify the operation of the contact closures. If
the correct speed is activated when the closure is
activated, the variable-speed pump starts, and the
message REMOTE ENABLED appears on the
controller display.
NOTE
When starting the pump via a remote closure, the
pump will first run at the priming speed for the
priming duration, as set by the installer.
2.10

Remote Operation

Speeds activated via remote closures always override
speeds that have been activated manually or via an internal
timer program. When the pump is activated via a remote
closure, the keypad is disabled and the message REMOTE
ENABLED appears on the display.
REMOTE ENABLED
10:00AM
2
MENU
The controller will remain in this state until the contact is
opened. When more than one (1) contact closure occurs, the
highest speed will take priority.
ePump™ and VS-FloPro™ Variable-Speed Pump Controller
Pump
Function
Address
Factory Default
JEP-R
PUMP 1
PUMP 2
AquaLink RS
AquaLink PDA
PUMP 3
PUMP 4
Factory Default
JEP-R
PUMP 1
PUMP 2
AquaLink RS
AquaLink PDA
PUMP 3
PUMP 4
RPM:1200
3
4
1
N/A
ON
ON
N/A
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
N/A
OFF
OFF
N/A
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
4 3 2 1
RS485
Figure 7.
Connection to Remote Contacts
2.11

Remote Closure 4 Behavior

The behavior of speed "4" differs from manual operation
when operated via a remote contact closure. As during manual
operation, the turn-on time of remote closure 4 is immediate,
and occurs at the same time as contact closure (For example,
see Section 2.8). The turn-off time, however, is delayed by 30
minutes.
In other words, when remote closure 4 is de-activated, the
variable-speed pump will continue to run for 30 minutes,
after which time the controller will turn off the variable-speed
pump. The delay may be manually interrupted by pressing
any speed key.
Remote Closure 4 Application -
Booster Pump Support
The behavior of remote closure 4 may be used to allow an
external timeclock fitted with a 20-minute "fireman's switch"
(e.g., Intermatic P/N 156T4042A) to properly control the
variable-speed pump in conjunction with a booster pump.
NOTE
Pump models JEP1.5, JEP2.0 allow for alternate
remote closure, or auxiliary load options. Please
see the pumps installation/owner's manual for more
information.
Connection for Booster Pump Support:
1.
Turn off all switches and the main breaker that
supplies power to the variable-speed pump.
|
Installation Manual
DIP Switch Setting
2
3
4
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Remote Contact
Closure
J3
REMOTE CONTROL
5 4 3 2 1
input
common
5
ON
ON
ON
ON
ON
ON
N/A
N/A
N/A
N/A
N/A
N/A

Publicidad

Tabla de contenido
loading

Tabla de contenido