Estar Speed; Pump Freeze Protect Operation; Selecting Pump Type; Display Power Usage - Zodiac JEP-R Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ePump™ and VS-FloPro™ Variable-Speed Pump Controller
To set priming duration, select PRIMING DURATION using
the arrow keys. Press MENU. Using the arrow keys, set the
priming speed to the desired value in minutes from one (1) to
five (5) minutes. Press MENU to accept and store.
PRIMING DURATION
MIN: 3
2
MENU
4.6

eStar Speed

The "
" speed is intended to be used as an energy-efficient
setting that can be easily called-up by activating the eStar
preset speed from the keypad or remote closure. After this
speed has been determined by the installer, the eStar speed
may be set as follows: From the service setup menu, select
SET ESTAR SPEED. Press MENU. Using the arrow keys,
set the speed to the desired value. Press MENU to accept and
store.
1:eSTAR
RPM:1250
2
MENU
4.7

Pump Freeze Protect Operation

When enabled to do so, the controller monitors the
temperature inside the pump and will activate the variable-
speed pump at the eStar speed when the temperature
approaches freezing. The run duration of the pump freeze
protect operation is adjustable from 30 minutes to 8 hours, or
may be disabled completely.
To set the pump freeze protect operation, from the service
setup menu select PUMP FREEZE PROTECT. Press
MENU. Using the arrow keys, set the duration to the desired
value. To disable pump freeze protect, set the duration to
0:00. Press MENU to accept and store.
PUMP FREEZE PROTECT
2
MENU
3
4
3
4
1:05
3
4
|
Installation Manual
Important Information on Freeze Protection
Freeze protection is intended to protect equipment and
plumbing for short periods of freezing only. It does this
by activating the filtration pump and circulating the water
to prevent freeze inside equipment or plumbing. Freeze
protection does not guarantee that equipment will not be
damaged by extended periods of freezing temperatures
or power outages. In these conditions, the pool and spa
should be shut down completely (e.g. drained of water and
closed for the winter) until warmer weather exists.
The pump freeze protect run time may be interrupted by
pressing a speed key, as follows:
Pressing the key "
" once overrides the pump freeze protect
run time, pressing it twice turns off the pump. Pressing other
speed keys will override the pump freeze protect run time and
activate the selected preset speed.
4.8

Selecting Pump Type

The controller may be used to operate various types of
pumps. It is important to select the correct pump type at this
menu item to ensure proper controller operation.
From the setup menu, select PUMP TYPE. Press the MENU
button to display the currently selected pump type. Using the
arrow keys, choose the pump type that matches the type of
the installed pump. Refer to the pump manual for information
regarding the pump type.
4.9

Display Power Usage

The controller can alternately display the variable-speed
pump power usage while the pump is in operation and the
controller is in Run Mode.
ENGLISH
Page 15

Publicidad

Tabla de contenido
loading

Tabla de contenido