Manual Start And Stop; Pump Speed Setting; Timeclock Setup And Operation - Zodiac JEP-R Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 12
ENGLISH
3.5

Manual Start and Stop

Up to eight (8) speeds may be started from the controller.
Manual operation of speeds "eStar" through "4" differs from
manual operation of speeds "5" through "8".
NOTE
When starting the pump, the pump will first run at the
priming speed for the priming duration, as set by the
installer.
Speeds eStar through 4
To start the pump manually running at speeds "eStar" through
"4", press button "
" through "4" corresponding to the
desired speed. The associated LED will light red and the
controller enters the RUN mode.
10:00AM
2
MENU
To stop the pump, press the button again. The associated LED
will extinguish and the pump and controller will return to the
OFF mode.
Speeds 5 through 8
To start the pump manually at speeds "5" through "8",
press the MENU button. The controller displays SELECT
PRESET/N:LABEL, where n:label is the number and label
of the last selected speed "5" through "8".
Using the arrow keys, select the desired speed to activate,
and then press MENU to enter RUN mode, starting the pump
running at the selected speed.
SELECT PRESET
2
MENU
To stop the pump, press MENU. To exit without starting the
pump, press any button "
3.6

Pump Speed Setting

With the exception of preset "
adjusted while the pump is running in that speed mode. Preset
"
" is reserved for the eStar function, and its speed is set by
the installer.
ePump™ and VS-FloPro™ Variable-Speed Pump Controller
2:SPEED 2
RPM: 1200
4
3
5:SPEED 5
4
3
" through "4".
", each speed may be
To adjust the pump speed, the controller must be in the RUN
mode. While in RUN mode, the controller displays the pump
speed. Adjust the speed by pressing the up or down arrow
keys. The speed is saved by the controller and will remain
until changed again.
NOTE
Pump speed is adjustable only within a certain range.
The minimum and maximum limits of the range are
set by the installer.
NOTE
When used with a solar heat system, set speed to
at least 3000 RPM and potentially up to 3450 RPM,
based on the pump's head required to push the water
up a minimum of 12-15 feet.
10:00AM
3.7

Timeclock Setup and Operation

NOTE
The controller has a non-replaceable battery back-up
that keeps time, programs, and speed settings when power is
disconnected and should never require replacement.
The controller allows the user to create timed pump programs
on pump speeds (presets) "
operate independently of each other, and may overlap in time
if desired.
Timeclock Setup
Start the desired speed, "
controller enters the Timeclock setup mode. Using the arrow
keys, select ON TIME and press MENU. Set the desired
pump turn-on time using the arrow keys and press MENU.
The time is stored. Select OFF TIME using the arrow keys
and press MENU. Set the desired pump turn-off time using
the arrow keys and press MENU. The time is stored.
2:SPEED 2 TIMECLOCK
Using the arrow keys, select TIMECLOCK. Select ENABLE
using the arrow keys. The program is now enabled to run.
Press the speed button ("
mode.
|
Installation Manual
2:SPEED 2
RPM: 1400
" and "2". The two timers
" or "2". Press MENU. The
ON TIME
" or "2") to return to the RUN