2
Technical data
General data
Conformity
Approvals
Degree of
protection
Vibration
resistance
Surface
temperature
Thermal contact
Design
Switching
capacity
Rated data
Type
ERBM100R100W
ERBM180R050W
ERBM390R100W
R
Resistance
B
P
Permanent power
d
C
Thermal capacity
B
V
Max. operating voltage
max
m
Mass
22
CE
Low−Voltage Directive
UR
UL508, Industrial Control
Equipment, Underwriter
Laboratories (File−No. E208678) for
USA and Canada
IP50
Acceleration
EN50178, IEC61800−5−1 and
resistant up
Germanischer Lloyd, general
to 1 g
conditions
In normal operation up to 300 °C
In case of an error more than 300 °C
NC contact, 200 °C
250 V AC/2 A
R
P
B
d
[W]
[W]
100
100
180
50
390
100
l
C
V
B
max
[kWs]
[V
]
DC
15
400
7.5
15
800
EDKRBM390R DE/EN/FR/ES/IT 2.0
m
[kg]
0.37
0.28
0.37