MOTOR (M1)
30 - 31 - 32 ENCODER (M1)
IMPORTANT:
Do not connect auxiliary relays or other devices tot he 18 V DC output (terminals 11 – 12)
to avoid malfunctions of the control unit. Use separated power supply / transformers
instead;
do not connect switching feeders or similar apparatus close to the automation that
may be a source of disturbance.
LOGIC ADJUSTMENTS
Make the logic adjustments.
Note: when any adjusting devices (trimmers or dip-switches) on the control panel are oper-
ated, a complete manoeuvre must be carried out in order for the new settings to take effect.
TRIMMER
T.R.A.
This trimmer may give some extra seconds – other than the ones already
set in learning mode – to the second gate leaf closing delay. Unless neces-
sary, leave it to the minimum value. By turning the trimmer clockwise will
increase the extra the second gate leaf closing delay;
T.C.A.
Automatic Closing Time adjustment: from about 1 to 120 seconds (see dip-
switch no. 1);
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gear-
motor to obstacles diminishes and therefore the thrust force increases; vice-
versa, by rotating it counter-clockwise, the sensitivity of the gearmotor to
obstacles increases and therefore the thrust force diminishes.
Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
CLOSES AGAIN
3
AFTER THE
PHOTOCELL
4
NO REVERSE
PRE-
5
FLASHING
6
FOTOTEST
motor (M1) supply output 18V DC max. 50 W.
(28= POSITIVE - 29= NEGATIVE)
encoder supply and input (30= WHITE signal - 31= BLUE
negative - 32= BROWN positive)
when completely open, closure is automatic after the set time on
On
the T.C.A. trimmer has past.
Off
the closing manoeuvre requires a manual command.
when the automation is operating, a sequence of opening/clos-
On
ing commands causes the automation to OPEN-CLOSE-OPEN-
CLOSE, etc.
in the same conditions, the same sequence of commands causes
Off
the automation to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc .
(step-by step function) (see also dip switch
after the photocell is activated (input 7 - 9), the automation closes
On
automatically after 5 seconds.
Off
function off.
On
the automation ignores the closure command during opening.
Off
the automation responds as established by dip switch No. 2.
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
On
the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
D749MA
4).
19