tau D749MA Guía Para La Instalación página 20

Ocultar thumbs Ver también para D749MA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
2
RADIO
nd
7
CHANNEL
MOTORS
8
SELECTION
9-10-11
Automation type selection
Dip 9
Dip 10
Off
Off
On
Off
Off
On
On
On
Off
Off
On
Off
Off
On
On
On
IMPORTANT: In case the automation type change, a new setting of the dips # 9, 10
and 11 will be required. Before the new setup, however, it is necessary to proceed
to a HARD RESET (see page 24) of the controller.
SENSITIVE
12
EDGE
MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing
the adjustment operations.
Note: the mechanical stops of the automation must be regulated both in opening and in
closing [see motor instructions].
When you have completed the installation procedures:
Check the position of dip-switches 9, 10 and 11. Dip-switches must be set according
to the automation model (see table of dip-switches 9-10-11, "Logic adjustments"
section).
Press without releasing the PROG button till the DL8 LED starts flashing (yellow):
-
the automation starts to open slowly looking for the opening limit stop;
Note: if the automation does not work, check the input connections. The DL6, DL5,
DL4 and DL3 green LEDS must be on.
-
once the limit stop is reached, the automation starts closing looking for the closing limit stop
(in this phase the control unit gathers all the parameters regarding the run);
-
the automation carries out one complete opening to optimize the opening power;
-
after a short pause, the automation carries out one complete closure to optimize the closing
power.
WARNING:
-
The procedure can be stopped by pressing the STOP button.
-
During the various stages of the operation, if the sensor is activated saving is stopped.
To restart the procedure from the beginning (with the DL8 yellow LED flashing), use the
AP/CH control, the remote control (if programmed) or press the PROG button briefly.
Please remember that an obstacle during saving is interpreted as a mechanical
limit stop (the system does not start any safety operation, it just stops the motors).
Make sure you don't stand near the automation during saving.
20
2 sec. monostable function: when the impulse from the remote
On
control is received, the contact is activated and remains like this
for 2 seconds.
Active bistable function: when the impulse from the remote control
Off
is received, the contact is activated and remains like this till the
following impulse.
On
enables just one motor (M1).
Off
enables 2 motors.
Dip 11 Automation
Off
ARM up to 400 Kg; EASY12QR; ZIP12
Off
ARM more than 400 Kg
Off
R18
Off
R40
On
B12ENC
On
not used
On
not used
On
not used
On
RESISTIVE SENSITIVE EDGE (terminal No. 10).
Off
FIXED EDGE (NC contact – terminal No. 10).
D749MA

Publicidad

Tabla de contenido
loading

Tabla de contenido