turning the unit ON and OFF may of course be
installed in the mains supply lead.
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
Mounting procedure
• Select appropriate site of installation, giving
consideration to sensor reach and detection
of movements (Fig� 3�3)
• Switch OFF power supply (Fig� 4�1)
• Mark drill holes (Fig� 5�1)
• Drill holes and insert wall plugs (Fig� 5�2)
– Concealed power supply lead (Fig� 5�2)
– Surface-mounted power supply lead
(Fig� 5�3)
• Connect conductors (Fig� 4�2)
• Make plug connection (B) (Fig� 5�4)
• Screw sensor unit (C) into place (Fig� 5�5)
• Switch ON power supply (Fig� 5�6)
• Make settings ➔ "6� Operation"
6� Operation
Operation/function legend (Fig� 6�1)
Note: After connecting to the mains power
supply, the white Status-LED flashes for 10 s.
The sensor is then ready for operation.
Factory settings
Time setting: Install (pos. 8)
Reach setting: 3x MAX
Light-level setting 1000 lux (pos. 7)
Functions
Time setting (Fig� 6�2 / H)
The time you wish the connected load to stay
ON for can be adjusted to any of six settings:
30 seconds, 1 minute, 2 minutes, 5 minutes,
15 minutes to 30 minutes.
Pulse mode (Fig� 6�2 / H)
If you set the control dial to
(pos� 1),
the unit is in pulse mode, i.e. the output is
switched ON for approx. 2 sec. (e.g. for
staircase lighting timer). Afterwards, the sensor
does not react to movement for approx. 8 s.
Install mode (Fig� 6�2 / H)
Install mode has the purpose of checking for
proper working order as well for testing the de-
tection zone. Irrespective of light level, the light
connected switches ON for 10 s in response to
movement (Status-LED flashes). Install mode
has priority over all other settings. Change
control dial setting to quit Install mode. When
making settings with the RC9 remote control,
Install mode ends automatically after 10 min.
Reach setting (Fig� 6�2 / I 1-3)
Reach can be infinitely adjusted in three direc-
tions via three control dials from 1-5 m (max.
approx. 7 m) independently of each other. The
maximum detection reach is selected via the
control dials.
Detection diagram (Fig� 6�3)
Note: if the distance to a wall or similar struc-
ture is less than 7 m in any of these directions,
the reach in that direction must still be set to
maximum reach or detection errors may be
made. The reach settings should only be used
to mask out areas in which you do not want
movement to result in light being switched ON.
Performance of the iHF 3D may also be
impaired by installing it in corners or on metal
building exteriors.
Light-level setting
(Response threshold) (Fig� 6�2 / J)
The sensor's chosen response threshold can
be infinitely varied from approximately 2 to
1000 lux.
Teach mode
Teach mode (Fig� 6�2 / J / pos� 8) saves the
current ambient light level below which you do
not want the sensor to respond to movement
from now on.
Manual override function (Fig� 6�4 / 6�5)
If a mains switch is installed in the mains
supply lead, the following functions are
provided in addition to simply switching light
ON and OFF:
16
Sensor mode: (Fig� 6�4)
– Switch light ON (when light is OFF):
– Switch OFF and ON once. Light stays ON for
the period selected.
– Switch light OFF (when light is ON):
– Switch OFF and ON once. Light goes out or
switches to sensor mode.
Manual override (Fig� 6�5)
– Activate manual override:
– Turn switch OFF and ON twice. The light
is set to manual override for 4 hours (Sta-
tus-LED ON). Then it returns automatically to
sensor mode (Status-LED OFF).
– Deactivate manual override:
– Switch OFF and ON once. Light goes out or
switches to sensor mode.
Important: The switch must be actuated in
rapid succession (in the 0.2 - 1 s range).
7� Accessories
Remote control RC9 (EAN 4007841007638)
Any number of iHF 3D sensors can be
controlled by the RC9 remote control. The
Status-LED on the sensor flashes (once) to
indicate each valid press of the button. The
Status-LED flashes (twice) to indicate each
valid press of the button. (Fig� 7�1)
Functions:
Light-level setting
The chosen response threshold can
1
be set from approx. 2-1000 lux.
Daylight operation
2
Night-time operation
3
4
Teach mode
This button must be pressed at the
level of light at which you want the
sensor to respond to movement
from now on.
The current value is stored.
Time setting
5
The period of time you want the
light to stay ON for after the last
detected movement can be set
to 10 s, 1 min, 5 min, 15 min by
pressing these buttons.
Light ON time
6
Setting the light to stay ON for a
time of your own choice. Each
press of the button increments
the current time setting by 1 min
(up to 30 min).
Manual override function
7
Pressing this button switches the
light ON for 4 hours (Status-LED
on). The light then returns to sensor
mode automatically. Pressing the
button for a second time (before the
4 h period expires) returns the light
to sensor mode.
Install mode
8
Install mode has the purpose of
checking for proper working order
as well for testing the detection
zone. Irrespective of light level, the
light switches ON for 10 s in re-
sponse to movement. (Status-LED
flashes).
Install mode has priority over all
other settings. Install mode ends
automatically after 10 min. Install
mode ends immediately after
pressing reset.
Note: Teach mode and Install
mode cannot be used at one
at the same time.
Reset
9
Resets all settings to the values
selected on the light manually or
to the factory settings.
Smart Remote (optional)
(EAN 4007841009151)
– Control by smartphone or tablet
– Replaces remote control
– Load appropriate app and connect via
Bluetooth
8� EC Declaration of Conformity
Hereby, STEINEL Vertrieb GmbH declares that
the radio equipment type iHF 3D 3D 3D is in
compliance with Directive 2014/53/EU. The
full text of the EU declaration of conformity
is available at the following internet address:
www.steinel.de
17