Electrical Requirements

Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation. Refer to the illustration below for minimum power
cord plug clearance.
Performance may be compromised if the electrical supply is
less than 240 volts.
EL EC T R IC A L R EQ UI R EM ENT S
Electrical Supply
Service
Receptacle
Power Cord
NEMA
PLUG
GROUNDED
NEMA RECEPTACLE
NEMA 6-20R receptacle
grounded, 240/208 VAC, 60 Hz
20 amp dedicated circuit
NEMA 6-20R grounding-type
6'
(1.8 m)
1"
(25)
MINIMUM
CORD
CLEARANCE
Power cord clearance
WARNING
ELECTRICAL SHOCK HAZARD: Plug into a grounded
3-prong outlet. Do not remove the ground prong. Do
not use an adapter. Failure to follow these instructions
can result in electric shock, fire, or death.

RATING PLATE

Rating plate location
|