3.3.2 t
«
»
urn off
step
sAfety deVice
«stop» stop key.
Turn off «step» by pressing the «on/off» key until the key
lighting is turned off (aprox 3 sec.).
3.4 t
urn on And off with the
connector
3.4.1 t
urn on
Power swith on.
«Step» socket: Connector for plug connector. Various
siwthing element possible.
Hold «run» button depressed.
Hold step «on/off» depressed briefly. The yellow edge
starts to blink.
Pre-select speed with key «+/-».
Press «enter» key.
Start or stop possible via connected switching element.
3.4.2 t
urn off
Press «stop» button.
Speed indicator blinks.
Hold step «on/off» button depressed approx. 3 s. The
blinking of the speed indictor extinguishes.
When changing tools or abrasives the «step»
function is always to be turned off with the «stop»
key.
3.5 i
s
i
nitiAtion
Afety
nstructions
During operation avoid sharp bendings of the flex-
ible shaft. Excessively small bend radius will result
in premature wear. Strong whipping movements
and convulsions of the flexible shaft are signs of overload-
ing. As countermeasures use smaller tool or increase ro-
tational speed. However, this only in stict observation of
the instructions on the maximum allowed circumferential
speed of the respective tool.
4.1 p
«
»
step
plug
4.1.1 m
age.
Keep cooling air openings unclogged.
Clean air filter daily. Remove filter from the machine and
blow out with compressed air or clean with water. Rein-
stall filter in dry condition. Replace as required.
Regularly check connection line. Have defective lines or
connectors replaced. Have repairs done by a technician
only.
Do not spray down with water. Clean surface with lightly
moistened rags.
4.1.2 m
In case of daily use lubricate monthly:
Pull shaft core out of protective tubing. Remove old shaft
grease. Lubricate shaft core with shaft grease only lightly
(1 kg can, order no. 904 832). Replace worn shaft core
(see SUHNER catalogue). Keep hose coupling in clean
- lightly greased condition. Replace worn couplings (see
SUHNER catalogue).
4.2 t
Display message: STEP
Lever of STEP circuit not pressed.
Press lever before «run» start command.
Malfunctions not listed here are to be repaired by a SUH-
NER repair service organization.
4.3 s
See page 4-9.
4. S
/ m
ervIce
reVentiVe mAintenAnce
AintenAnce of the mAchine
Before any maintenance work is carried
out, pull out the power connector!
Dry the machine and keep clean in stor-
AintenAnce of the flexiBle shAft
Store flexible shafts in dry and clean condition.
New or freshly greased shafts require a run-in
time of approx. 1 hour.