jbc ADVANCED JT 7000 Serie Manual De Instrucciones página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Exchanging the resistor from the heater.
1. Move back the spring. Untighten the screws.
2. To take out the resistor, press down the lower
part of the heater on a fixed surface.
3. Separate the resistor from the heater's cable.
4. Connect the new resistor, pushing it's extreme.
5. Fix the screws tightly to avoid air-loss which
could reduce the resistor's lifetime. Finally put
the spring back in it's place.
OPERATING INCIDENTS
The suction cup does not adhere to the
component.
Deficient aspiration, Vacuum.
1 Verify if the suction cup is well placed and in
perfect condition.
2 Check the incoming air filter in the interior of
the station and replace it if dirty or obstructed.
Filter
Ref. 0861800
Error messages
Whenever the ERR message appears, the
equipment turns itself off completely.
The following messages are displayed:
- BLANK SCREEN
Power failure.
Check for blown fuses.
- ERR 1
The temperature will not rise.
Possible causes:
· Heating element open.
· In case of a long low-power period.
7
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido