- ERR 3
No reading from the thermocouple.
Possible cause: open thermocouple.
- ERR 6
Insufficient air flow which causes an excesive
rise of the heating temperature.
Before recuperating this type of error you must
wait until the temperature goes down.
Possible causes: leaking or blocked air conducts
or faulty self-contained air pump.
- ERR 8
Faulty reading of the rotationsmeter of the self-
contained air pump.
Possible causes: air pump damaged or faulty
function of the optical sensor circuit.
To recuperate any of these errors actuate the
general switch at the back of the station, the
pedal should not be pushed at this moment.
Temperature sealing-cover
Accessory which replaces the
selection temperature button and
it is use to prevent operators
from changing the temperature
that has been pre-selected.
Indicates
the
temperature.
JBC reserves the right to make technical changes without
prior notification.