english
If the wires slip out of the connector, get a
new connector and repeat steps 1 and 2.
Maximum wire run between the control mod-
ule and the solenoid should be as follows:
Wire Size (AWG)
Maximum Distance (ft)
Wire Size (mm
2
)
Maximum Distance (M)
3. Check the system by using the manual start
command on the TBOS Field Transmitter. If
the irrigation system does not start, tighten
the latching solenoid by hand.
Mounting the Control Module
To mount the Control Module to the valve box:
1. Screw two mounting screws (not included)
into the side of the valve box. (See fig. D.)
2. Slide the Control Module's mounting key
holes over the screws; press down to secure.
3. Tighten the mounting screws.
18
16
14
32
50
80
0,75
1,5
2,5
10
15
24
8
TBOS
™
Control Module
Automatic Self-Cleaning
Solenoid Plunger Feature
Every night at 3AM, the Control Module sends a
signal to the solenoid to turn it on and then off.
This cycle lasts about three seconds. This pre-
ventative maintenance feature is intended to
keep the solenoid plunger clean for maximum
reliability.
Maintaining the Control Module
To keep your TBOS Control Module in working
order:
• Replace the battery once a year. We recom-
mend you use a high-quality alkaline battery,
such as Energizer.
Note: If the Control Module battery is dead,
any programs stored in the Control
Module are lost. If the battery still has
power, when you change the battery any
english