Problem:
Faulty transmission
Possible cause: The battery is weak.
Solution:
Replace the battery.
Possible cause: The battery contact is faulty.
Solution:
Tighten the connectors to ensure a
tight battery connection.
Possible cause: The Control Module connector is
dirty.
Solution:
Clean the connector.
Possible cause: The connection between the Field
Transmitter and the Control Module
is loose.
Solution:
Make sure you have a snug Field
Transmitter-to-Control Module con-
nection. Repeat the transmission sev-
eral times.
12
TBOS
™
Control Module
Possible cause: The microprocessor did not reset
properly.
Solution:
Remove the battery. Short the Control
Module battery clip (not the battery)
contacts together with a paper clip or
other piece of metal for 30 seconds.
Reinstall a fresh battery.
Possible cause: You are attempting to retrieve an
even, odd or 1 through 6 day program
with a UNIK
Solution:
Use a TBOS Field Transmitter to
retrieve advanced programs.
Problem:
Station does not start
Possible cause: No run time has been programmed
for that station.
Solution:
Transmit a run time to the Control
Module.