Description And Operation; Stationary Wet-Well Installation; Electrical Connection - Wilo Drain TS 40/10 Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para Drain TS 40/10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
English

6 Description and operation

6.1 Pump description (Figure 1)
Pos.
Part description
1
Cable assy
2
Head Cover
3
Adaptor cover
4
Motorhousing
5
Non-return valve
6
Pipe connection 1 ½"
7
Delivery port, Flange
8
Gasket, Flange
9
Cover, Casing
10
Pump casing
11
Floatswitch
12
Cable holder
13
Sealing, cable entry
The submersible motor pump is driven by an
enclosed motor that is impermeable to presswa-
ter. Motor and pump have a continuous shaft. The
flow medium enters from below through the cen-
tral suction opening and exits by the vertical pres-
sure-pipe connection. The pump has a built-in
non return valve (pos. 5).
The TS 40 pumps are delivered with a half-open
impeller (pos. 23). It pumps solids up to 10 mm Ø
(no fibrous materials such as grass, leaves or rags).
For stationary installation, the pump is screwed to
a fixed pressure-pipe (R 1½), and for transporta-
ble installation to a hose connection.
The motor of both types is sealed with a mechan-
ical tandem seal (pos. 20) on the medium and
motor side against the pump housing. So that the
seals are lubricated and cooled in the case of dry
running, the chamber between the mechanical
seals is filled with oil.
CAUTION! Risk of leak!
If the mechanical seal is damaged, small quanti-
ties of oil may leak into the flow medium.
The motors are fitted with a thermal motor pro-
tection (1
~
thermal motor control) that automatically
switches the motor of if there is a threat of it over-
heating and switches it back on again once it has
cooled down. A capacitor is fitted at the 1
to generate the rotary field.
7 Installation and electrical connection
Installation and electrical connection should be
carried out in accordance with local regulations
and only by qualified personnel!
WARNING! Risk of personal injury!
The relevant accident precaution regulations
must be observed.
WARNING! Risk of electric shock!
Potential dangers caused by electrical energy
must be excluded.
Local or general regulations [e.g. IEC, VDE, etc.]
and directives from local energy supply compa-
nies are to be followed.
10
: thermal winding contact (WSK), 3
Pos.
Part description
14
Capacitor
15
Gasket, Head Cover
16
End bracket (B)
17
Rotor assy
18
Stator
19
End bracket (A)
20
Mechanical seal
21
Oil drain plug with seal
22
Washer
23
Impeller
24
Gasket, Casing
25
Strainer
26
Hose nozzle R1½ (outside thread)
7.1 Installation
The pump is designed for stationary and trans-
portable wet-well installation.
CAUTION! Risk of damage to the pump!
• Only suspend the pump using a chain or rope
from the transport loop, never by the electric
cable or pipe / hose connection.
• When the pump is lowered into the shaft or pit
the connecting cable must not be damaged.
• The pump must be installed in a frost-free place.
• The shaft must be free from coarse solids (e.g.
building rubble) prior to installation and commis-
sioning.
• See catalogue for installation dimensions.
• The pressure-pipe must show the pump's nominal
width (R 1½, possibility for expansion).

7.1.1 Stationary wet-well installation

In the case of stationary wet-well installation of
TS 40 pumps with pressure-pipe the pump is to be
positioned and secured such that:
• the pressure-pipe connections do not bear the
weight of the pump,
:
• the load of the pressure-pipe does not act on the
~
connecting sleeve.
7.1.2 Transportable wet-well installation
motor
In transportable wet-well installations, the pump
~
in the shaft is to be protected against tipping over
and slipping. (e.g. secure the chain with slight pre-
stressing).
NOTE:
If used in pits without a solid floor, the pump must
be placed on a sufficiently large plate or be sus-
pended in a suitable position on a rope or chain.

7.2 Electrical connection

WARNING! Risk of electric shock!
Electrical connection must be carried out by an
electrical installer authorised by the local power
supply company in accordance with the applica-
ble local regulations (e.g. VDE regulations).
• Check that the mains current and voltage comply
with the data on the rating plate.
Wilo AG 05/2006

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Drain ts 40/14Drain ts 40/10 aDrain ts 40/14 a

Tabla de contenido