Application; Risk Of Explosion; Product Information; Technical Data - Wilo Medana PE3-350EA Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
5

Application

6

Product information

6.1

Technical data

6.2

Scope of delivery

7

Description and function

7.1

Key to drawings

Installation and operating instructions Wilo-Medana PE3
Application
Handle the product with care so as not to damage it prior to installation.
These devices are domestic pressure boosting systems designed for clean water. The
downward type is designed for boosting water from roof-top water tank to lower floors
using water and the upward type is designed for boosting water from tank on the
ground to upper floors.
DANGER

Risk of explosion!

Do not use this pump to convey flammable or explosive liquids.
Medana PE3-350EA
Hydraulic data
Maximum operating pressure
Maximum suction pressure
Maximum altitude
DN of suction connection
DN of pressure connection
Temperature range
Fluid temperature range
Ambient temperature
Electrical data
Motor protection rating
Insulation class
Frequency
Voltage
Other
Max. sound level
ƒ
Multistage horizontal automatic pump
ƒ
Installation and operating instruction
ƒ
Accessory assy (pressure Tank: 0.3L)
Figure 1
1.
Stop valve on the suction side
2.
Stop valve on the discharge side
3.
Hopper cap
4.
Pressure tank
5.
Drain screw
6.
Pipe support
7.
Strainer
8.
Water tank
9.
Piping
5
1.8 bar (1.8 x 10
Pa)
5
Mode 1: 0.8 bar (0.8 x 10
Pa)
5
Mode 2: 1.3 bar (1.3 x 10
Pa)
1000m
1"
1"
+5°C to +35°C
Max. +40°C
IPX4
B130
50Hz
1~ 220-230V
45 dB(A)
en
9

Publicidad

Tabla de contenido
loading

Tabla de contenido