  • ESPAÑOL, página 24
• The pump should be protected against moisture,
frost and physical damage during transport and
interim storage.
4 Applications
DANGER! Risk of electric shock!
The pump may not be used for draining swim-
ming-pools / garden ponds or similar places
when there are people in the water.
WARNING! Risk of personal injury!
• The materials are not designed for drinking
water supply.
The pump must not be used for pumping drink-
ing water.
• The pumps must not be used:
• to pump raw sewage containing faeces,
• in potentially explosive locations,
Local regulations must be observed.
The submersible motor pumps of the Wilo-Drain
TS 40 are suitable for removing dirty water and
clear fluids containing solids of max. 10 mm Ø
from shafts, pits and vessels.
They are used:
• for building and surface dewatering,
• in sewage and water-management,
• in environmental and domestic waste disposal,
• in industrial and process engineering.
5.2

Technical data

Permissible components of the flow
media:
max. permissible grain size:
Mains voltage:
Mains frequency:
System of protection:
Speed:
max. current consumption:
Power input P1:
Motor power rating P2:
max. flow rate:
max. pump lift:
Operating mode S1:
Operating mode S3 (optimum):
recommended operating frequency:
max. operating frequency:
Nominal width of pipe mount:
Temperature range of the flow medium:
max. immersion depth:
Oil filling:

5.3 Scope of supply

Each pump is supplied with
• 5 / 10 m connecting cable,
• plug (earthing pin), (for single-phase current)
• built-in non return valve,
• connected float switch (A-version),
• hose connection 1½",
• pipe connection with outside thread 1½",

• Installation and operating instructions.

Installation and operating instructions Wilo-Drain TS 40

5 Product data

5.1 Type code
Example:
TS
40
/10
A
1-230
-50
-2
-10M KA
Mildly acidic / mildly alkaline,
Chloride content max. 150 mg/l (for 1.4301 / AISI 304),
10 mm
±
1
230 V,
10 %, 3
400 V,
~
~
50 Hz
IP 68
1
max. 2900
/min (50 Hz)
see rating plate
see rating plate
see rating plate
see rating plate
see rating plate
200 operating hours a year
Intermittent service, 25 % (2.5 min mode, 7.5 min break).
1
20
/
h
1
50
/
h
see rating plate
+3 to 35 °C
5 m
ELFOLNA DS 22 or comparable, 410 ml
The pumps
• are made from stainless steel (1.4301) and plastic
(hydraulic).
• are normally submerged by the flow medium,
• can be installed stationary or transportable, but
only vertically.
TS 40/10 A 1-230-50-2-5M KA,
TS 40/14 3-400-50-2-10M KA
Series: submersible motor pump, waste water
Nominal width: 40 = Rp 1½
Maximum pump lift [m]: 10, 14
A = with float switch, connecting cable with
plug
- = not specified: without float switch, con-
necting cable with free cable end for
3
motor
~
Mains voltage: 1
230 V, single-phase motor,
~
3
400 V, three-phase motor
~
Mains frequency [Hz]
2 poles
Connecting cable length [m]: 5, 10
±
10 %