Installation to Solid Concrete or Cinder Block
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all at-
tached hardware and components.
Make sure that wall plate (A) is level, use it as a
1
template to mark six mounting holes. The top mounting
slots should be located 7" (177 mm) above the desired
screen center as shown in figure 1.1 page 4. Drill six
1/4" (6 mm) dia. holes to a minimum depth of 2.5"
(64 mm). Insert anchors (D) in holes flush with wall
as shown (right). Place wall plate over anchors and
secure with six #14 x 2.5" screws (C). Level, then
tighten all fasteners.
WARNING
• Tighten screws so that wall plate is firmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• Always attach concrete anchors directly to load-
bearing concrete.
• Never attach concrete anchors to concrete covered
with plaster, drywall, or other finishing material. If
mounting to concrete surfaces covered with a finish-
ing surface is unavoidable, the finishing surface must
be counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when tight-
ening screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer (not
evaluated by UL).
INCoRReCT
wall
plate
plaster/
dry wall
Visit the Peerless Web Site at www.peerlessmounts.com
CoRReCT
concrete
wall plate
plaster/
dry wall
WARNING
1
Drill holes and insert anchors (D).
2
Place plate (A) over anchors (D) and secure with screws (C)
3
Apriete todas las fijaciones.
concrete
5 of 24
A
C
D
A
C