Start off
When the gate is standstill and it begins moving, the initial inertia must
be faced, therefore, if your gate is quite heavy, its doors could not
move.
SPUn
In case the
(pickup) function is activated, for the first 2 seconds
Pot
of motion of each door, the control unit will ignore
value and it will
give motor the maximum power command in order to overcome the
gate inertia.
Starting ramp
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
Adjusting the obstacle sensor
This menu allows adjustment of the sensitivity of the obstacle sensor.
When the current absorbed by the motor exceeds the value set, the
control unit detects an alarm.
For sensor operation, please refer to the dedicated section 10
no
amperometric disabled
Slow down in opening
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last opening stretch.
Slow Down in Closing
This menu allows regulating the percentage of the ride/drive that is
carried out at reduced speed during the last closing stretch.
56