Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase.
PAUS
The gate stops and goes to pause.
ChiU
The gate immediately starts closing.
no
The gate go on with the opening phase (command is ignored).
PAUS
Select option
, to set up the "step-by-step" operation logic.
no
Select option
, to set up the 'always open' operation logic
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase.
StoP
The gate stops and its cycle is considered as finished.
APEr
The gate opens again.
StoP
Select option
, to set up the "step-by-step" operation logic.
APEr
Select option
, to set up the 'always open' operation logic.
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the gate is open during its pause phase.
ChiU
the gate starts closing
no
command is ignored
PAUS
the pause time is reset (
ChiU
Select option
, to set up the "step-by-step" operation logic.
no
Select option
, to set up the "always open" operation logic.
ATTENTION: Apart from selected option, the start command
lets the gate close if it has been stopped by a stop command or if
the automatic closing was not enabled.
Pedestrian Start during the partial opening phase
This menu allows fixing the control unit conduct in case it receives a
Pedestrian Start command during the partial opening phase.
PAUS
The gate stops and goes to pause
ChiU
the gate immediately starts closing
no
the gate goes on with the opening phase (command is ignored)
WARNING: a Start command in any phase of partial opening
will cause the total opening; the Start Pedestrian command is
always ignored during a total opening.
57
Ch.AU
)