IO-Link Data Dictionary
21.10.01.00115/00
IO-Link Implementation
Observation
Monitoring
Process Data
40
0x0028
0
Process Data In Copy
Sensor Value
64
0x0040
1
64
0x0040
2
Sensor Value LO
64
0x0040
3
Sensor Value HI
Supply Voltage
66
0x0042
1
Supply Voltage LO
66
0x0042
2
66
0x0042
3
Supply Voltage HI
Communication Mode
Communication Mode
564
0x0234
0
Counters
140
0x008C
0
cc1
Counter cc1
Counter cc2
141
0x008D
0
cc2
143
0x008F
0
ct1
Counter ct1
144
0x0090
0
ct2
Counter ct2
Diagnosis
Device Status
Error Count
32
0x0020
0
36
0x0024
0
IO-Link Device Status
37
0x0025
1-15
Detailed Device Status
Active Error Code
130
0x0082
0
138
0x008A
1
Extended Device Status - Type
138
0x008A
2
Extended Device Status - ID
Condition Monitoring [CM]
146
0x0092
0
Condition Monitoring
160
0x00A0
0
Actual Leakage Rate
J. Schmalz GmbH
2 bytes
ro
2 bytes
ro
2 bytes
ro
2 bytes
ro
2 bytes
ro
2 bytes
ro
2 bytes
ro
1 byte
ro
4 bytes
ro
4 bytes
ro
4 bytes
ro
4 bytes
ro
2 bytes
ro
1 byte
ro
15 x 3 bytes
ro
1 byte
ro
1 byte
ro
2 bytes
ro
1 byte
ro
2 bytes
ro
5 of 6
SMP FS RP
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
info@schmalz.de
Copy of currently active process data input
Actual sensor value
Lowest measured sensor value since power-up
Highest measured sensor value since power-up
Supply voltage as measured by the device (unit: 0.1 Volt)
Lowest measured supply voltage since power-up
Highest measured supply voltage since power-up
0x00 = SIO mode
0x10 = IO-Link revision 1.0 (set by master)
0x11 = IO-Link revision 1.1 (set by master)
Switch-on counter for switch point 1 (non-erasable)
Switch-on counter for switch point 2 (non-erasable)
Switch-on counter for switch point 1 (erasable)
Switch-on counter for switch point 2 (erasable)
Number of errors since last power-up
0 = Device is operating properly
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
Information about currently pending events
Fixed-length array format according to IO-Link specification V1.1
0 = No error
1-99 = Error code displayed by the device
Type code of active device status (see below)
ID code of active device status (see below)
Bit 2: Leakage rate above limit -L- (not for VSi P10)
Bit 5: Primary voltage US outside of optimal range
Leakage rate, unit mbar/sec (not for VSi P10)
13.03.2018
VSi Data Dictionary