Ideal Vol-Con XL Manual De Instrucciones página 2

Ocultar thumbs Ver también para Vol-Con XL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ND 3401-1 61-085/086 Vol-Con In
• Do not use during electrical storms or
in wet weather.
• Do not use around explosive gas, dust,
or vapor.
• Do not apply more than the rated volt-
age to the tester. Voltage is not to
exceed 600V.
• Always operate this solenoid-type tester
within the specified duty cycle on the
front of the tester. Duty cycle ratio is:
• 1:15 ON:OFF time.
• Maximum ON time is 15 seconds.
• Do not use without batteries and cap
properly installed.
• Remove test leads prior to removing
battery cap.
Caution
To protect yourself, think "Safety First":
• Voltages exceeding 30VAC or 60VDC
pose a shock hazard so use caution.
• Never ground yourself when taking
electrical measurements.
• Use appropriate personal protective
equipment such as safety glasses, face
shields, insulating gloves, insulating
boots, and/or insulating mats.
• Use the 3-Step Testing Method. Before
each use:
• Perform a continuity test by touching
the probe tips together, an audible
sound should be heard and the con-
tinuity LED should light. This test
verifies the functionality of the batter-
ies and test leads (61-086 only).
1/9/07
4:29 PM
Page 2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vol-test61-08661-085

Tabla de contenido