and the ground, only the continuity light
should turn "On," indicating neutral and
ground are connected. If the " – DC"
light also turns "On," there is 6VAC or
greater between neutral and ground
indicating a high resistance leakage to
ground. High resistance leakage is
qualified since a low resistance (high
current) leak to ground would open a
circuit breaker or blow a fuse.
Battery Replacement: (61-086 only)
• Replace batteries when touching the
leads together no longer lights the con-
tinuity LED or produces an audible
sound.
• Remove test leads from tester.
• Loosen the encapsulated screw from the
bottom of the case.
• Remove battery cap.
• Replace the batteries with (4) new 1.5V
button-type batteries (IDEAL# 61-201,
IEC #LR44, or NEOA# 1166A).
• Replace battery cap and re-tighten the
encapsulated screw.
Test Lead Replacement:
• Replace leads only with IDEAL test
leads below.
• # TL-80 Standard Test Leads with
Shielded Probe Tips
• # TL-82 Resistor-fused Test Leads
with Shielded Probe Tips. Each
probe tip contains a special, current-
limiting resistor which acts like a fuse
to limit short-circuit current and pre-