Descargar Imprimir esta página

Publicidad

Enlaces rápidos

WARNINGS AND CAUTIONS
• TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER or fuse and test that the power is off before wiring
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, contact a electrician.
DESCRIPTION
Leviton Data Protection Modules (Cat. Nos. 3803-DHP and 3803-485) are designed as the
primary line of protection from data line impulses and transients. The Data Protection Module is
to be connected as a series Surge Protective Device (SPD) in the data line. Use Belden 9463 or
equivalent cable for the connection of Cat. No. 3803-DHP. Use Belden 9842 or equivalent cable
for the connection of Cat. No. 3803-485.
SPECIFICATIONS
Maximum DC Operating Voltage:
9.6V DC
Clamping Voltage:
81V
Maximum Surge Current:
1kA
Strike Breakdown Voltage:
13V @ 100V per micro-second
10.5V @ 100V per second
Maximum Capacitance A-B Lines: L-L: 2.2 pf, L-G: 73 pf
Operating Temperature Range:
-40°C - 60°C
Storage Temperature Range:
-40°C to 90°C
Relative Humidity:
0 to 95% non-condensing
Altitude:
-1000 ft. to 15000 ft.
Tested to UL 497B
Solid state semi-conductor SPD circuitry for:
• 3803-DHP (Line to Line protection and both Line 1 and Line 2 to Ground).
• 3803-485 (Line to Line protection and Lines A, B, Com, Shld & Term to GND).
• SPDs are enclosed in a non-conductive ABS case. ABS is a flame retardant
thermoplastic, compliant with UL 497B polymeric material test requirements.
• SPDs are intended for use in data bus applications and essentially require
approximately a 5vdc potential difference. The voltage for SPDs are specifically
intended for a range from -4.5 to +4.5 VDC. Maximum continuous operating voltage is
9.6VDC.
INSTALLATION
1. WARNING: TO AVOID FIRE SHOCK OR DEATH, TURN OFF POWER at the installation
location by unplugging the data cable and turning the equipment power OFF.
2. Locate the Data Protection Module so that the SPD connections can be easily inserted into
the data cable without excessive tension on the wiring connections (Fig. 4).
3. Connect the Data Protection Module to chassis ground using the metallic base plate and/or
the attached braided cable. DO NOT ADD ANY EXTENSION TO THE "BRAIDED CABLE
TO GROUND" PATH.
WIRING PROCEDURE
FOR CAT. NO. 3803-DHP:
WARNING: TO AVOID FIRE SHOCK OR DEATH, TURN OFF EQUIPMENT POWER AND
DISCONNECT THE DATA CABLE AT THE SPD INSTALLATION LOCATION.
Cut the data cable, as shown in Fig. 4, and connect the cable to the 3803-DHP input and
output connectors as follows and shown in Figs. 1 and 2A:
1. Slip a large diameter piece of shrink tubing over both ends of the cut cable.
2. Remove 1" (25.4 mm) of the outer jacket from the cut ends of the data cable.
NOTE: Be sure YOU DO NOT cut the drain wire shorter than the other wires as it is used for
connection to the "SHLD" (Shield) terminal.
3. Remove excess length of the exposed portions of the foil shield, braided shield, and filler
cords from the cable.
4. Remove 0.125" (3.2 mm) of insulation from the end of each conductor wire.
5. Tin the Blue conductor wire, the clear conductor wire and the drain wire with solder.
6. Insert the tinned wires into the 3803-DHP connector terminals, as shown in Fig. 2A and
tighten the retaining screws.
7. Position the shrink tubing as required and apply the necessary heat for strain relief.
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and
proper use for five years from the purchase date. Leviton's only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This
warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind,
including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and
fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com
8. Plug the connectors into the appropriate "Input" and "Output" [PLC (Programmable Logic
Controlled)/SLC (Small Logic Controlled) load side locations] on the 3803-DHP module, as
shown in Fig. 3A.
9. Reconnect the modified equipment cable, as shown in Fig. 4.
POWER ON: Following data cable reconnection to the equipment, restore power to the
installation circuit by turning the power ON. INSTALLATION IS COMPLETE.
FOR CAT. NO. 3803-485:
WARNING: TO AVOID FIRE SHOCK OR DEATH, TURN OFF EQUIPMENT POWER AND
DISCONNECT THE DATA CABLE WHERE SPD PROTECTION IS REQUIRED.
Cut the data cable as located in Fig. 4 and connect the cable to the 485 input and output
connectors as follows and shown in Figs. 1 and 2B.
1. Slip a large diameter piece of shrink tubing over both ends of the cut cable. Using wire
strippers, remove 1" (25.4 mm) of the outer jacket from the cut ends of the data cable.
NOTE: Be sure YOU DO NOT cut the drain wire shorter than the other wires as it is used for
connection to the "SHLD" (Shield) terminal.
2. Remove 1" (25.4 mm) of the braided shield under the PVC jacket and cut back the two White
insulation strands.
3. Cut OFF the White-Blue stripe wire of the Blue-White stripe/White-Blue stripe pair. It is not
used with this device.
4. Remove 0.25" (6.4 mm) of insulation off the Orange-White stripe/White-Orange stripe pair.
DO NOT tin the wire tips.
5. Remove 0.25" (6.4 mm) of insulation off the Blue-White stripe wire. DO NOT tin the wire tips.
NOTE: Unless otherwise directed by existing wiring system requirements perform steps 6 to
10 as shown in Fig. 2B.
6. Twist the strands and insert the Orange-White stripe wire into terminal 5 (A).
7. Twist the strands and insert the White-Orange stripe wire into terminal 4 (B).
8. Twist the strands and insert the Blue-White stripe wire into the terminal 3 "COM" location.
9. Insert the shield/drain wire (non-jacketed) into Terminal 2 (SHLD).
10. Position the shrink tubing to prevent the end of shield from fraying and apply the necessary
heat for strain relief.
11. Plug the connectors into the appropriate "Input" and "Output" (PLC/SLC load side) locations
on the 485 module, as shown in Fig. 3B.
12. Reconnect the modified equipment cable as shown in Fig. 4.
POWER ON: Following data cable reconnection to the equipment, restore power to the
installation circuit by turning the power ON. INSTALLATION IS COMPLETE.
Fig. 1 – Typical Cable Construction
Fig. 1 – Composants d'un câble type
Fig. 1 – Construcción de Cable
Braided Shield
Blindage tressé
Protección Trensada
Foil Shield
Blindage métallique
Lámina de Protección
Outer Jacket
Drain Wire
Gaine
Fil de masse
Forro Exterior
Cable de Descarga
Filler Cord
Fil de garniture
Relleno de Cordón
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
SURGE PROTECTIVE DEVICES
Cat. Nos. 3803-DHP and 3803-485 Networks
WARNINGS AND CAUTIONS
• Incorrect assembly or installation may result in fire, electrical property damage, shock, personal injury, or death.
• Use this device with copper or copper clad wire.
INSTALLATION INSTRUCTIONS
Fig. 2A – 3803-DHP Terminal Connections
Fig. 2A – Connexions aux bornes du modèle 3803-DHP
Fig. 2A – Conexiones Terminales del Módulo 3803-DHP
Terminales en un Bloque Terminal de 3 Puntas
Clear/Translucide/Transparente
1
Shield/Blindage/Protegido
SHLD
Blue/Bleu/Azul
2
Fig. 3A – 3803-DHP Input/Output Connections
Fig. 3A – Connexions d'entrée/de sortie du modèle 3803-DHP
Fig. 3A – Conexiones de Entrada y Salida Del Módulo 3803-DHP
Conectores Terminales de 3 Puntas (2 incluídos)
3-Pin Headers (2)
Collecteurs à 3 broches (2)
Cabezales de 3 puntas (2)
Braided Ground Wire
Câble de masse tressé
Cable Trensado a Tierra
Fig. 4 – Insert Data Protection Module Cat. No. 3803-DHP
or 3803-485 at any one of the locations marked "X"
Insulation
Fig. 4 – Insérer le module à n'importe lequel des endroits
Isolant
marqués d'un « X ».
Aislante
Clear Conductor Wire
Fig. 4 – Inserte el Módulo de Protección de Data No. de Cat. 3803-DHP
Conducteur Translucide
o 3803-485 en cualquier lugar marcado con "X"
Conductor Transparente
Blue Conductor Wire
Conducteur bleu
Conductor Azul
Insulation
Isolant
Aislante
Terminals On 3-Pin Terminal Block
Bornes des connecteurs à 3 broches
Clear/Translucide/Transparente
1
Shield/Blindage/Protegido
SHLD
Blue/Bleu/Azul
Twinlead Cable
2
Câble bifilaire
Cable de 2 Conductores
Fig. 3B – Connexions d'entrée/de sortie du modèle 3803-485
Fig. 3B – Conexiones de Entrada y Salida Del Módulo 3803-485
3-Pin Terminal Connectors (2 Included)
Connecteurs à 3 broches (2 fournis)
Retaining Screws
Collecteurs à 6 broches (2)
Vis de retenue
Cabezales de 6 puntas (2)
Tornillos de Retención
Brass Terminal Plate
Connected To Ground
Plaque en laiton
raccordée à la masse
Placa Terminal de Latón
Conectada a Tierra
Communication Cable
Câble de transmission de données
Cable de Comunicación
Personal Computer
Ordinateur personnel
Computador Personal
DI-000-03803-20F
ENGLISH
Fig. 2B – 3803-485 Terminal Connections
Fig. 2B – Connexions aux bornes du modèle 3803-485
Fig. 2B – Conexiones Terminales del Módulo 3803-485
Orange-White Stripe
Orange-blanc
Rayado Anaranjado-Blanco
6
TERM
White-Orange Stripe
Blanc-Orange
5
A
Rayado Blanco-Anaranjado
4
B
Belden 9842 Cable
Câble Belden 9842
3
COM
Belden 9842 Cable
2
SHLD
Shield/Drain
Blindage/masse
1
CHS GND
Blue-White Stripe
Protegido/Descarga
Bleu-blanc
Rayado Azul-Blanco
Fig. 3B – 3803-485 Input/Output Connections
6-Pin Terminal Connectors (2 Included)
Connecteurs à 6 broches (2 fournis)
Conectores Terminales de 6 Puntas (2 incluídos)
Retaining Screws
Vis de retenue
6-Pin Headers (2)
Tornillos de Retención
Brass Terminal Pla
Connected To Grou
Plaque en laiton
raccordée à la mass
Placa Terminal de L
Conectada a Tierra
Braided Ground Wire
Câble de masse tressé
Cable Trensado a Tierra
Coupler
Controller
Coupleur
Contrôleur
Acoplador
Controlador
Cable/Câble/Cable
Controller
Coupler
Contrôleur
Coupleur
Controlador
Acoplador
Cable/Câble/Cable
Coupler
Controller
Coupleur
Contrôleur
Acoplador
Controlador
Cable/Câble/Cable

Publicidad

loading

Resumen de contenidos para Leviton 3803-DHP

  • Página 1 LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and...
  • Página 2 Leviton garantiza al consumidor original de sus productos y no para beneficio de nadie más que este producto en el momento de su venta por Leviton está libre de defectos en materiales o fabricación por un período de cinco años...

Este manual también es adecuado para:

3803-485