INSTRUCTIONS FOR USE
When the connection of the electrical conductors has
been made, you may set the desired value of time de-
lay to the disconnection by operating with the setting
screw. When you rotate it in clockwise direction, the
disconnection time delay is prolonged, in such a way
that the led blinks each time it jumps to the next delay
level.
After placing the key, the device is ready to be effi-
ciently used.
When operating manually on the key, the controlled
element will connect to the Timer Switch. The discon-
nection of the latter will be automatically produced
when the previously set time delay is over.
If the key, or any of the auxiliary push-buttons, if any,
is operated before the totality of the set time delay has
come to an end, the device re-initialises the time se-
quence