GENERAL DESCRIPTION

The ARTIC 8000 charger is ideal to charge most lead-acid batteries, often used for cars and many other vehicles. The ARTIC can
be used safely for : GEL (gel electrolyte), AGM (Absorbant Glass Mat), WET, MF (Maintenance Free), CA (Calcium)...
The ARTIC 8000 charger is designed for charging 12V batteries (6 x 2V elements) from 4 Ah to 160 Ah et up to 240 Ah for a main-
tenance charge.
START UP
1. Connect the charger to the battery using the proper accessory (clamps, lugs, etc...).
2. Plug the charger to the mains (single phase 220-240Vac 50-60Hz). The display shows the battery voltage.
3. Select the mode by pressing button
4. During the charge, the device indicates the voltage and the charge progress using the symbol
fully charged, the symbol
5. The charge can be interrupted at any time by unplugging the mains plug or pressing the
6. After the charge, disconnect the charger from the mains, then disconnect the charger's connections from the battery.
CHARGE MODES
• Modes description :
CHARGE mode «SLOW» 12V (14.4 V / 2 A) :
This mode limits the charging current to 2 A to safely charge small batteries. Activate this option to charge small
batteries (< 15 Ah).
CHARGE mode «FAST» 12V (14.4 V / 8 A) :
This mode is designed for lead-acid batteries, 12V from 15 Ah to 160 Ah and up to 240 Ah for floating charge.
CHARGE mode 12V COLD option (14.7 V / 8 A) :
This mode modifies the charging voltage at 14.7V to charge the battery during cold weather (less than 5°C) or for
some AGM batteries or batteries with caps.
• Estimated charge time
Battery capacity
Charging time 20% >>> 80%
6
ARTIC 8000
, the charge starts automatically.
is displayed.
SLOW
4 Ah
8 Ah
15 Ah
2 h
3 h
7 h
FAST
20 Ah
50 Ah
100 Ah
2 h
5 h
9 h
EN
. When the battery is
button.
160 Ah
14 h