Calibration - Gram RZ Serie Manual De Utilización

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

turns on .The higher the setting, the slower stabilization time.
P13
Precondition for zeroing or taring setting:
stable :Taring or zeroing can be not action without stable indication after pressing the
key
or
always:Taring or zeroing can be action without stable indication after pressing the key
or
auto: Press key
P14
Weight memory parameter
On: display the last weight when powering on again
Off: do not display the last weight when powering on again
P15
Parameter initialization
Press key

CALIBRATION

Note: Before calibration, please set the capacity first. The unit used in calibration is the one
that has been set before. During the calibration procedure, long press
normal weighing mode without saving.
Here we take 3kg/0.2g as an example
1. Press and hold
2. With no load on the weighing pan, press
3. Wait till the window displays the first calibration value.
Note: The first calibration value is default. If the value has been changed, the default value is
1/3 of full load.
or
, but it works only when get the stable indication.
then key
to start initialization. It is finished when displaying OK.
while powering on, not release it till the window displays
to start zero point calibration.
to return to
CAL"
"
11

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rz-6Rz-15Rz-30

Tabla de contenido