Inspect and clean blower
Check that the impeller rotates freely. Vacuum or wipe clean all surfaces.
Inspect and clean desiccant rotor
Ensure that rotor is clear of dust and debris.
Vacuum or use pressurized air to remove dust from rotor.
Inspect rotor belt. Check cracks or excessive wear. Contact your local distributor for replacement instructions.
Vacuum interior to remove dust and debris. Wipe interior surfaces with clean, dry cloth. Do not apply water or cleaning
solutions of any kind. Take care not to damage electronic sensors and wires.
Reattach side panel. Reattach sensor cable inside panel. Thread the cable up through the zip tie and then plug in the
cable. Now install screws, finger tight only, starting at the top and working down. Once all screws are properly started,
then use a hand tool to tighten the screws snugly. Do not overtighten. Do not use a power tool to tighten screws.

PUMP PURGE BUTTON

The Control Panel will display the following messages when the Pump Purge Button is pressed.
C O N T R O L P A N E L
M E S S A G E
PLEASE WAIT
CALCULATING
PERFORMANCE
XXX PINTS/24H

SYSTEM MESSAGES

The Control Panel will display the following messages based on system performance and environmental conditions. User
action, if any is required, is indicated in the third column.
C O N T R O L P A N E L
M E S S A G E
INITIALIZING
FIRMWARE VERSION
XXX
F533-XX
OFF/ON
PLEASE WAIT
WARMING UP
UNIT ON XXXX HRS
INLET XXX°F / XX%
HUMIDISTAT
INLET XXX°F / XX%
PLEASE WAIT
COOLING
XXXXX
POWER FAILURE>
CLEAN FILTER >
XXXXX
CLEAN ROTOR >
XXXXX
49-109J F533
Unit is calculating water removal.
Displays calculated water removal in units indicated per day.
E X P L A N A T I O N
Unit is powering up.
Indicates control board firmware version number.
Model number.
Unit has finished powering up and is operating.
Fan will not operate until unit reaches proper operating
temperature, approximately 10 seconds..
First line: indicates total operating hours.
Second line: Toggles between inlet temperature and in-
let RH every 2 seconds.
First line: indicates unit is in humidistat mode
Second line: Toggles between inlet temperature and in-
let RH every 2 seconds.
Fan will operate until unit cools down. Approx 30 sec-
onds.
Indicates power has been interrupted during operation.
Prompt to clean or change filter.
Prompt to clean rotor.
E X P L A N A T I O N
7
U S E R A C T I O N
None
None
None
None
None
None
None
None
Press the > key to reset
Change or clean filter. Press
the > key to reset
Clean rotor. Press the > key
to reset