Campbell Hausfeld Cast Iron Serie Instrucciones De Operación página 4

Ocultar thumbs Ver también para Cast Iron Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Installation
(Continued)
TO CHANGE TO THE ALTERNATE VOLT-
AGE ON THREE PHASE MOTORS WITH
230/460 RATINGS
1. Rewire motor per data plate on
motor or instruction sheet.
2. Check electric rating of magnetic
starter and replace thermal overload
elements or magnetic starter as
required. The voltage and amperage
ratings are listed on the motor
nameplate.
DIRECTION OF ROTATION
NOTE: Improper rotation will result in
reduced unit life.
The direction of rotation must be coun-
terclockwise (as shown by the arrow on
the flywheel) while facing the flywheel
side of the pump. The motor nameplate
will show wiring information for coun-
terclockwise rotation.
The proper direction is very important.
The direction of rotation of 3 phase
motors can be reversed by interchang-
ing any two motor-line leads. For single
phase motors, refer to the motor name-
plate.
IMPORTANT: CHECK MOTOR ROTATION
BEFORE OPERATING THE COMPRESSOR.
Operation
All lubricated compressor pumps dis-
charge some condensed water and oil
with the compressed air. Install appro-
priate water/oil removal equipment and
controls as necessary for the intended
application.
Failure to install
NOTICE
!
appropriate
water/oil removal equipment may result
in damage to machinery or workpiece.
GUARDING
The belt guard provided
must be installed before
operating the unit.
All moving parts must be guarded. All
electrical covers must be installed
before turning on the power.
Pump
Pressure
Gauge
Drain Cock
Isolation Pad
Figure 4 - Component Identification
LUBRICATION
THIS UNIT CONTAINS
NO OIL. Before
operating compressor, fill crankcase
with compressor oil according to the
oil capacity chart.
Oil Capacity
Some residual oil may still be in the
pump leaving a thin coat on the sight
glass, however; there is not enough oil
to operate the unit. Fill pump with sin-
gle-viscosity, ISO100 (SAE 30), non-
detergent, compressor oil. Add oil only
through the oil fill plug. Pouring oil
into any other orifice will cause oil to
leak and spray out during operation.
Fill to the center of the sight gauge.
NOTE: Use of automotive engine oil
will cause carbon deposits to build up
on the valves. This will shorten the life
expectancy and will require more fre-
quent service to the valves. Do not use
ATF hydraulic fluid, two-cycle oil or any
oil treatment product. Do not use
diester synthetic oil.
4
Discharge
Tube
Safety Valve
Breather
Cap
1.4 Qt.
Sight
Gauge
IMPORTANT: After draining oil,
remove sight gauge and wipe entire-
ly clean. Reinstall then fill pump
with fresh oil.
Figure 5
RECOMMENDED BREAK-IN PERIOD
The compressor should be run continu-
ously for one hour to allow proper seat-
ing of the piston rings.
1. Open drain cock completely and run
the compressor for 60 minutes.
Cast Iron Series
Motor
Pressure
Switch
Tank Shut-off Valve
Discharge Port
Tank
(Available Separately)
Oil
Fill Plug
Oil
Drain
Plug
Full
Low

Publicidad

Tabla de contenido
loading

Tabla de contenido