Condition
A. PUMP WILL NOT START OR
RUN.
B. PUMP STARTS TOO SOON.
C. WATER LEVEL EXCESSIVE
BEFORE PUMP TURNS ON.
D. PUMP WILL NOT SHUT OFF
OR RUNS TOO LONG BEFORE
WATER IS PUMPED.
E. PUMP OPERATES BUT DELIVERS
LITTLE OR NO WATER.
Before servicing a pump, always shut off
the main power breaker and then unplug the pump
- making sure you are not standing in water and are
wearing insulated protective sole shoes. Under flooded
conditions, contact your local electric company or a qualified
licensed electrician for disconnecting electrical service prior
to pump removal.
Submersible pumps contain oil which become
pressured and hot under operating conditions - allow 2½
hours after disconnecting before attempting service.
If the above checklist does not solve the problem, consult
Zoeller Technical Service Department 1-(800) 928-PUMP
- Do not attempt to service or otherwise disassemble
pump.
Possible Cause
Low voltage, blown fuse, open
circuit.
Impeller bound.
Motor or wiring shorted.
Debris on float switch.
Float "ON" point is adjusted too
low.
Float "ON" point adjusted to high.
Pump not plugged into piggyback
float switch receptacle.
Debris under float.
Faulty float switch.
Float "Off" point adjusted too low.
Pump is air locked.
Water level too low.
Waste material has accumulated
blocking flow of material.
Debris around intake.
Blockage in discharge pipe.
Low or incorrect voltage.
Damaged Impeller.
Incorrect float adjustment.
Pump is air locked.
Vertical lift too high.
disposable diapers, dish rags, etc. in the QWIK JON ®
ULTIMA . They may jam the pump or other plumbing lines
and cause malfunction.
CARE OF FINISH: Soap and water is all that is recommended
for cleaning the outside of the tank. Other cleaning products
may cause discoloration and scratching.
© Copyright 2012 Zoeller Co. All rights reserved.
4
Remedy
Have a qualified electrician check fuse
and circuit.
Contact a Zoeller Service Station.
Remove debris
Raise the float stops, make sure the
float is between the two stops.
Lower the upper float stop.
Ensure pump is not plugged directly
into the outlet. Plug pump into
piggyback float switch receptacle.
Remove debris from around float.
Contact a Zoeller Service Station.
Raise the lower float stop.
Make sure vent hole in discharge
pipe is clear.
Raise the lower float stop.
Hold flush handle down on toilet
for 15 seconds. If unit will not clear,
unplug and wait 30 minutes. Plug
unit back in and repeat. If unit still
will not turn off, it will need to be
opened and the debris relocated.
Clean area around intake.
Remove pipe and flush out debris.
Have a qualified electrician check
house wiring.
Contact a Zoeller Service Station.
Contact Technical Service
Department.
Make sure vent hole in discharge
pipe is clear.
Change discharge piping or contact
Technical Service Department.