Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

G
SYSTEM LAY-OUT
B

TECHNICAL DATA

Power supply
Absorption
Accessories power supply
1-leaf maximum speed
2-leaf maximum speed
1-leaf maximum capacity
2-leaf maximum capacity
Type and frequency of use
Temperature
Degree of protection
The type and frequency of use are only indicative. They are collected under average
conditions of use and cannot be definite for each single case.
Each automatic access may be affected by variable elements such as: friction, balancing
and environmental factors, which may substantially alter both the duration and the
EN16005 ELECTRIC CONNECTION
SLIDER 120
230 V~ / 50-60 Hz
1 A
28 Vdc/0,5 A MAX
0,8 m/s
1,6 m/s
120 kg
80+80 kg
S3 = 100%
-20°C / +55°C
Batteries: -10°C/+50°C
IP20
4
2
1
3
7
SLIDER 160
230 V~ / 50-60 Hz
1 A (1,6 A with weight > 200 kg)
28 Vdc/0,5 A MAX
0,8 m/s
1,6 m/s (1,2 m/s with weight > 180 kg)
160 kg
130+130kg
S3 = 100%
-20°C / +55°C
IP20
performance characteristics of the automatic access or parts thereof.
The installer shall be responsible for adopting suitable safety conditions for each particular
installation.
REF.
CODE
1
SLI0006
6
SLI0001
2
SLI0002
3x1,5 mm²
ACG9508
3*
ACG9630
4*
ACG9460
5
5*
ACG9425
6*
ACG9454
7
* OPTIONAL
Operation and performance are only guaranteed
with RIB devices and accessories.
28
Batteries: -10°C/+50°C
DESCRIPTION
Motor reducer
120 control unit
160 control unit
Batteries
KIT 2 batteries with cables and fuse
Sensor of command and protection
EN16005 certified.
DAY / NIGHT selector
Central electric lock
Power supply
ATTENTION:
1

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Slider 120Slider 160

Tabla de contenido