EN16005 ELECTRIC CONNECTION
brown
white
yellow
green
Code ACG9460
CONNECTION OF 2 RADAR FOR COMMAND
AND SAFETY (ACG9560) FOR 1 DOOR WITH
ACTIVE AUTOTEST (PARAMETER P=1)
NOTE: IF STOP PUSH-BUTTON IS NOT PRESENT,
CONNECT TERMINAL 18 WITH TERMINAL 8.
TO SELECT PARAMETER P=1 (PHOTOTEST ACTIVATED)
YOU NEED TO HAVE THE LCD PROGRAMMER AVAILABLE
AT LEAST DURING THE PROGRAMMING OF THE DOOR
code ACG9418 (FOR RECESS) - code ACG9419 (FOR
WALL).
ACG9460
2.5 m
20 cm
Code ACG9459 - ACG9460
CONNECTION OF 2 RADAR FOR COMMAND
AND SAFETY (ACG9560) AND 1 RADAR
FOR SAFETY (ACG9459) FOR 1 DOOR WITH
ACTIVE AUTOTEST (PARAMETER P=1)
NOTE: A POSSIBLE STOP PUSH-BUTTON MUST BE
CONNECTED IN SERIES TO THE PINK WIRE OF THE
RADAR FOR SAFETY (ACG9459).
TO SELECT PARAMETER P=1 (PHOTOTEST ACTIVATED)
YOU NEED TO HAVE THE LCD PROGRAMMER AVAILABLE
AT LEAST DURING THE PROGRAMMING OF THE DOOR
code ACG9418 (FOR RECESS) - code ACG9419 (FOR
WALL).
ACG9459
2.5 m
20 cm
ACG9460
2.5 m
20 cm
LED
+
-
30
29
28
CONNECTION OF 2 RADAR FOR COMMAND AND SAFETY (ACG9560) FOR 1 DOOR WITH ACTIVE AUTOTEST (PARAMETER P=1)
NOTE: IF STOP PUSH-BUTTON IS NOT PRESENT, CONNECT TERMINAL 18 WITH TERMINAL 8
CONNECTION OF 2 RADAR FOR COMMAND AND SAFETY (ACG9560) AND 1 RADAR FOR SAFETY (ACG9459) FOR 1 DOOR WITH ACTIVE AUTOTEST (PARAMETE
NOTE: A POSSIBLE STOP PUSH-BUTTON MUST BE CONNECTED IN SERIES TO THE PINK WIRE OF THE RADAR FOR SAFETY (ACG9459)
WHITE AND YELLOW WIRES
NOT CONNECTED
LED BAR
code ACG9442 - code ACG9443 - code ACG9444
29
STOP
WHITE
ACG9460 RADAR
YELLOW
FOR COMMAND AND SAFETY
INTERNAL
WHITE
ACG9460 RADAR
YELLOW
FOR COMMAND AND SAFETY
EXTERNAL
STOP
WHITE
ACG9460 RADAR
YELLOW
FOR COMMAND AND SAFETY
INTERNAL
WHITE
ACG9460 RADAR
YELLOW
FOR COMMAND AND SAFETY
EXTERNAL
ACG9459 RADAR FOR SAFETY
Requested
to
protect
movement of the leaf which
opens against a side wall.
PINK
GREY
RED
BLUE
GREEN
BROWN
PINK
GREY
RED
BLUE
GREEN
BROWN
PINK
GREY
RED
BLUE
GREEN
BROWN
PINK
GREY
RED
BLUE
GREEN
BROWN
PINK
GREY
RED
BLUE
GREEN
BROWN
G
B
2